BrachyGuide: a brachytherapy‐dedicated DICOM RT viewer and interface to Monte Carlo simulation software

机译:BrachyGuide:专门用于近距离放射治疗的DICOM RT查看器并与Monte Carlo模拟软件接口

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This work presents BrachyGuide, a brachytherapy‐dedicated software tool for the automatic preparation of input files for Monte Carlo simulation from treatment plans exported in DICOM RT format, and results of calculations performed for its benchmarking. Three plans were prepared using two computational models, the image series of a water sphere and a multicatheter breast brachytherapy patient, for each of two commercially available treatment planning systems: BrachyVision and Oncentra Brachy. One plan involved a single source dwell position of an 192Ir HDR source (VS2000 or mHDR‐v2) at the center of the water sphere using the TG43 algorithm, and the other two corresponded to the TG43 and advanced dose calculation algorithm for the multicatheter breast brachytherapy patient. Monte Carlo input files were prepared using BrachyGuide and simulations were performed with MCNP v.6.1. For the TG43 patient plans, the Monte Carlo computational model was manually edited in the prepared input files to resemble TG43 dosimetry assumptions. Hence all DICOM RT dose exports were equivalent to corresponding simulation results and their comparison was used for benchmarking the use of BrachyGuide. Monte Carlo simulation results and corresponding DICOM RT dose exports agree within type A uncertainties in the majority of points in the computational models. Treatment planning system, algorithm, and source specific differences greater than type A uncertainties were also observed, but these were explained by treatment planning system‐related issues and other sources of type B uncertainty. These differences have to be taken into account in commissioning procedures of brachytherapy dosimetry algorithms. BrachyGuide is accurate and effective for use in the preparation of commissioning tests for new brachytherapy dosimetry algorithms as a user‐oriented commissioning tool and the expedition of retrospective patient cohort studies of dosimetry planning.PACS numbers: 87.53.Bn, 87.53.Jw, 87.55.D‐, 87.55.Qr, 87.55.km, 87.55.K‐
机译:这项工作介绍了BrachyGuide,这是一种近距离放射治疗专用的软件工具,用于从以DICOM RT格式导出的治疗计划中自动准备用于Monte Carlo模拟的输入文件,并进行基准测试的计算结果。针对两个商业可用的治疗计划系统:BrachyVision和Oncentra Brachy,使用两个计算模型(水球和多导管乳房近距离放射治疗患者的图像系列)准备了三个计划。一个计划涉及一个 192 Ir HDR源(VS2000或mHDR-v2)位于水球中心,使用TG43算法,另外两个对应于多导管乳房近距离放射治疗患者的TG43和高级剂量计算算法。使用BrachyGuide准备了Monte Carlo输入文件,并使用MCNP v.6.1进行了模拟。对于TG43患者计划,在准备好的输入文件中手动编辑了Monte Carlo计算模型,以类似于TG43剂量学假设。因此,所有DICOM RT剂量输出都等同于相应的模拟结果,并且将它们的比较用于基准BrachyGuide的使用。蒙特卡罗模拟结果和相应的DICOM RT剂量输出在计算模型中大多数点的A型不确定性内是一致的。还观察到治疗计划系统,算法和来源特异性差异大于A型不确定性,但这些是由与治疗规划系统相关的问题和其他B型不确定性来源引起的。在近距离放射剂量学算法的调试过程中必须考虑这些差异。 BrachyGuide是准确有效的工具,可用于准备新的近距离放射治疗剂量学算法的试运行测试,将其作为面向用户的调试工具以及对剂量学计划进行回顾性患者队列研究的远征.PACS编号:87.53.Bn,87.53.Jw,87.55。 D‐,87.55.Qr,87.55.km,87.55.K‐

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号