首页> 美国卫生研究院文献>Journal of the International Society of Sports Nutrition >Effects of ingesting JavaFit Energy Extreme functional coffee on aerobic and anaerobic fitness markers in recreationally-active coffee consumers
【2h】

Effects of ingesting JavaFit Energy Extreme functional coffee on aerobic and anaerobic fitness markers in recreationally-active coffee consumers

机译:摄取JavaFit Energy Extreme功能咖啡对休闲型咖啡消费者中有氧和无氧健身指标的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to examine the effects of ingesting JavaFit™ Energy Extreme (JEE) on aerobic and anaerobic performance measures in recreationally-active male and female coffee drinkers. Five male (27.6 ± 4.2 yrs, 93.2 ± 11.7 kg, 181.6 ± 6.9 cm) and five female (29 ± 4.6 yrs, 61.5 ± 9.2 kg, 167.6 ± 6.9 cm) regular coffee drinkers (i.e., 223.9 ± 62.7 mg·d-1 of caffeine) participated in this study. In a cross-over, randomized design, participants performed a baseline (BASELINE) graded treadmill test (GXT) for peak VO2 assessment and a Wingate test for peak power. Approximately 3–4 d following BASELINE testing, participants returned to the lab for the first trial and ingested 354 ml of either JEE or decaffeinated coffee (DECAF), after which they performed a GXT and Wingate test. Criterion measures during the GXT included an assessment of peakVO2 at maximal exercise, as well as VO2 at 3 minutes and 10 minutes post-exercise. Additionally, time-to-exhaustion (TTE), maximal RPE, mean heart rate (HR), mean systolic pressure (SBP), and mean diastolic blood pressure (DBP) were measured during each condition. Criterion measures for the Wingate included mean HR, SBP, DBP, peak power, and time to peak power (TTP). Participants then returned to the lab approximately one week later to perform the second trial under the same conditions as the first, except consuming the remaining coffee. Data were analyzed using a one way ANOVA (p < 0.05). Our results indicate that JEE significantly increased VO2 at 3 minutes post-exercise when compared to BASELINE (p = 0.04) and DECAF (p = 0.02) values, which may be beneficial in enhancing post-exercise fat metabolism.
机译:这项研究的目的是研究摄取JavaFit™能量至尊(JEE)对有娱乐活动的男性和女性咖啡饮用者的有氧和无氧性能指标的影响。五名男性(27.6±4.2岁,93.2±11.7公斤,181.6±6.9厘米)和五名女性(29±4.6岁,61.5±9.2公斤,167.6±6.9厘米)定期喝咖啡(223.9±62.7 mg·d <咖啡因的sup> -1 )参加了这项研究。在交叉,随机设计中,参与者进行了基线(BASELINE)分级跑步机测试(GXT)以评估VO2峰值,并执行Wingate测试以评估峰值功率。在进行BASELINE测试后大约3-4天,参与者返回实验室进行第一次试验,并摄入354毫升的JEE或脱咖啡因的咖啡(DECAF),然后进行GXT和Wingate测试。 GXT期间的标准测量包括评估最大运动时的VO2峰值以及运动后3分钟和10分钟的VO2。此外,在每种情况下都测量了疲惫时间(TTE),最大RPE,平均心率(HR),平均收缩压(SBP)和平均舒张压(DBP)。 Wingate的衡量标准包括平均HR,SBP,DBP,峰值功率和峰值时间(TTP)。然后,参与者大约一个星期后返回实验室,在与第一次咖啡相同的条件下进行了第二次咖啡测试,只是消耗了剩余的咖啡。使用单向方差分析分析数据(p <0.05)。我们的结果表明,与基线(p = 0.04)和DECAF(p = 0.02)值相比,运动后3分钟JEE显着增加了VO2,这可能有助于增强运动后的脂肪代谢。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号