首页> 美国卫生研究院文献>Scientific Reports >Vital Recorder—a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices
【2h】

Vital Recorder—a free research tool for automatic recording of high-resolution time-synchronised physiological data from multiple anaesthesia devices

机译:Vital Recorder-一种免费的研究工具用于自动记录来自多种麻醉设备的高分辨率时间同步的生理数据

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The current anaesthesia information management system (AIMS) has limited capability for the acquisition of high-quality vital signs data. We have developed a Vital Recorder program to overcome the disadvantages of AIMS and to support research. Physiological data of surgical patients were collected from 10 operating rooms using the Vital Recorder. The basic equipment used were a patient monitor, the anaesthesia machine, and the bispectral index (BIS) monitor. Infusion pumps, cardiac output monitors, regional oximeter, and rapid infusion device were added as required. The automatic recording option was used exclusively and the status of recording was frequently checked through web monitoring. Automatic recording was successful in 98.5% (4,272/4,335) cases during eight months of operation. The total recorded time was 13,489 h (3.2 ± 1.9 h/case). The Vital Recorder’s automatic recording and remote monitoring capabilities enabled us to record physiological big data with minimal effort. The Vital Recorder also provided time-synchronised data captured from a variety of devices to facilitate an integrated analysis of vital signs data. The free distribution of the Vital Recorder is expected to improve data access for researchers attempting physiological data studies and to eliminate inequalities in research opportunities due to differences in data collection capabilities.
机译:当前的麻醉信息管理系统(AIMS)在获取高质量生命体征数据方面的能力有限。我们已经开发了Vital Recorder程序,以克服AIMS的缺点并支持研究。使用Vital Recorder从10个手术室收集手术患者的生理数据。使用的基本设备是病人监护仪,麻醉机和双光谱指数(BIS)监护仪。根据需要添加了输液泵,心输出量监测器,区域血氧仪和快速输液设备。仅使用了自动录制选项,并且经常通过Web监视来检查录制状态。在八个月的手术过程中,自动记录成功完成了98.5%(4,272 / 4,335)。记录的总时间为13,489 h(3.2±1.9 h /箱)。 Vital Recorder的自动记录和远程监视功能使我们能够以最小的努力记录生理上的大数据。生命记录仪还提供了从各种设备捕获的时间同步数据,以促进生命体征数据的集成分析。 Vital Recorder的免费分发有望改善尝试进行生理数据研究的研究人员的数据访问,并消除由于数据收集能力的差异而导致的研究机会不平等。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号