首页> 美国卫生研究院文献>Oncology Letters >A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes
【2h】

A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes

机译:基于纵隔淋巴结三维建模的胸腔放疗剂量学模型研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the present study was to investigate the optimal strategy and dosimetric measurement of thoracic radiotherapy based on three-dimensional (3D) modeling of mediastinal lymph nodes (MLNs). A 3D model of MLNs was constructed from a Chinese Visible Human female dataset. Image registration and fusion between reconstructed MLNs and original chest computed tomography (CT) images was conducted in the Eclipse™ treatment planning system (TPS). There were three plans, including 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), which were designed based on 10 cases of simulated lung lesions (SLLs) and MLNs. The quality of these plans was evaluated via examining indexes, including conformity index (CI), homogeneity index and clinical target volume (CTV) coverage. Dose-volume histogram analysis was performed on SLL, MLNs and organs at risk (OARs). A Chengdu Dosimetric Phantom (CDP) was then drilled at specific MLNs according to 20 patients with thoracic tumors and of a medium-build. These plans were repeated on fused MLNs and CDP CT images in the Eclipse™ TPS. Radiation doses at the SLLs and MLNs of the CDP were measured and compared with calculated doses. The established 3D MLN model demonstrated the spatial location of MLNs and adjacent structures. Precise image registration and fusion were conducted between reconstructed MLNs and the original chest CT or CDP CT images. IMRT demonstrated greater values in CI, CTV coverage and OAR (lungs and spinal cord) protection, compared with 3D-CRT and VMAT (P<0.05). The deviation between the measured and calculated doses was within ± 10% at SLL, and at the 2R and 7th MLN stations. In conclusion, the 3D MLN model can benefit plan optimization and dosimetric measurement of thoracic radiotherapy, and when combined with CDP, it may provide a tool for clinical dosimetric monitoring.
机译:本研究的目的是研究基于纵隔淋巴结(MLNs)的三维(3D)建模的胸部放疗的最佳策略和剂量测量。从中国可见人类女性数据集构建了MLN的3D模型。在Eclipse™治疗计划系统(TPS)中进行了图像配准以及重建的MLN与原始胸部计算机断层扫描(CT)图像之间的融合。根据10例模拟肺部病变(SLLs)和MLNs设计了3种计划,包括3D适形放射疗法(3D-CRT),强度调制放射疗法(IMRT)和体积调制弧光疗法(VMAT)。这些计划的质量通过检查指标进行评估,包括合格指数(CI),同质性指数和临床目标量(CTV)覆盖率。对SLL,MLN和高危器官(OAR)进行剂量-体积直方图分析。然后根据20名胸肿瘤和中等身材的患者,在特定的MLN上钻了一个成都剂量幻影(CDP)。在Eclipse™TPS中对融合的MLN和CDP CT图像重复了这些计划。测量CDP的SLL和MLN处的辐射剂量,并将其与计算的剂量进行比较。建立的3D MLN模型展示了MLN和相邻结构的空间位置。在重建的MLN与原始胸部CT或CDP CT图像之间进行精确的图像配准和融合。与3D-CRT和VMAT相比,IMRT在CI,CTV覆盖率和OAR(肺和脊髓)保护方面显示出更高的价值(P <0.05)。在SLL以及2R和第7 MLN站,测量剂量与计算剂量之间的偏差在±10%以内。总而言之,3D MLN模型可以优化计划和胸腔放疗的剂量学测量,并且与CDP结合使用时,它可以为临床剂量学监测提供工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号