The aim of this paper was to study sound source localization by cochlear implant (CI) listeners with low-frequency (LF) acoustic hearing in both the operated ear and in the contralateral ear. Eight CI listeners had symmetrical LF acoustic hearing (symm) and four had asymmetric LF acoustic hearing (asymm). The effects of two variables were assessed: (i) the symmetry of the LF thresholds in the two ears and (ii) the presence/absence of bilateral acoustic amplification. Stimuli consisted of low-pass, high pass, and wide-band noise bursts presented in the frontal horizontal plane. Localization accuracy was 23 degrees of error for the symm listeners and 76 degrees of error for the asymm listeners. The presence of a unilateral CI used in conjunction with bilateral LF acoustic hearing does not impair sound source localization accuracy, but amplification for acoustic hearing can be detrimental to sound source localization accuracy.
机译:本文的目的是研究耳蜗植入(CI)听众在手术耳朵和对侧耳朵中的低频(LF)听觉的声源定位。 8位CI听众具有对称的低频听觉(symm),另外4位具有不对称低频听觉(asymm)。评估了两个变量的影响:(i)两只耳朵的LF阈值的对称性,以及(ii)是否存在双边声音放大。刺激包括在正面水平面呈现的低通,高通和宽带噪声突发。对于symm侦听器,定位精度为23度错误,对于asymm侦听器,定位精度为76度错误。与双边LF声学听力一起使用的单边CI不会损害声源定位精度,但是声学听力的放大会损害声源定位精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号