Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry

机译:骨水泥和非骨水泥在牛津内侧UKA之间的相似聚乙烯磨损:使用放射立体测量法对79位患者进行的为期5年的随访随机对照试验

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background and purpose — Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing.Patients and methods — 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score.Results — The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02–0.07) for the cemented group and 0.05 mm/year (CI 0.02–0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI –0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1–5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up.Interpretation — The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang.
机译:背景与目的-羟基磷灰石(HA)涂层植入物与髋关节置换术中聚乙烯的高度磨损有关。 HA涂层在膝关节置换术中促进磨损的作用尚未得到研究。我们比较了聚乙烯骨水泥和非骨水泥HA涂层的牛津内侧单icon突膝关节置换术(UKA)的磨损率。其次,我们调查了磨损率是否受到轴承的悬垂或撞击的影响。患者和方法-将80例(平均年龄64岁)经治疗盲的患者随机分配到3个牛津内侧UKA版本中的1个:固结于双钉或单钉股骨组件或无骨水泥HA涂层双钉股骨组件(比率1:1:1)。我们比较了硬骨水泥组(n = 55)和非骨水泥组(n = 25)(比率2:1)之间的磨损。使用放射立体测量法对手术和5年随访之间的磨损,撞击和悬突进行定量。用牛津膝关节评分评估临床结局。结果-骨水泥组的平均磨损率为0.04 mm /年(95%CI 0.02–0.07),0.05毫米/年(CI 0.02–0.08)对于非骨水泥组。磨损的平均差异为0.008mm /年(CI –0.04至0.03)。没有发现碰撞。半数患者的内侧轴承悬垂,平均2.5 mm(1-5)。悬垂每增加1 mm,磨损就增加0.014mm /年。在5年的随访中,非骨水泥组的平均牛津膝关节评分为39,而骨水泥组的平均牛津膝关节评分为38。 。但是,警告是相对于平均磨损率差异的95%CI。组件的尺寸和位置很重要,因为一半的患者由于内侧轴承悬垂而导致磨损率进一步增加。

著录项

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号