Superior fixation and less periprosthetic stress-shielding of tibial components with a finned stem versus an I-beam block stem: a randomized RSA and DXA study with minimum 5 years’ follow-up

机译:鳍状茎与I型钢块茎相比胫骨组件固定效果好假体周围的应力屏蔽较小:随机RSA和DXA研究至少随访5年

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background and purpose — The stem on the tibial component of total knee arthroplasty provides mechanical resistance to lift-off, shear forces, and torque. We compared tibial components with finned stems (FS) and I-beam block stems (IS) to assess differences in implant migration.Patients and methods — In a patient-blinded RCT, 54 patients/knees (15 men) with knee osteoarthritis at a mean age of 77 years (70–90) were randomly allocated to receive tibial components with either a FS (n = 27) or an IS (n = 27). Through 5 to 7 years’ follow-up, implant migration was measured with RSA, periprosthetic bone mineral density (BMD) was measured with DXA, and surgeons reported American Knee Society Score (AKSS).Results — At minimum 5 years’ follow-up, maximum total point motion (MTPM) was higher (p = 0.04) for IS (1.48 mm, 95% CI 0.81–2.16) than for FS (0.85 mm, CI 0.38–1.32) tibial components. Likewise, total rotation (TR) was higher (p = 0.03) for IS (1.51˚, CI 0.78–2.24) than for FS (0.81˚, CI 0.36–1.27). Tibial components with IS externally rotated 0.50° (CI –0.06 to 1.06) while FS internally rotated 0.09° (CI –0.20 to 0.38) (p = 0.03). Periprosthetic bone stress-shielding was higher (p < 0.01) up to 2 years’ follow-up for IS compared with FS in the regions medial to the stem (–13% vs. –2%) and posterior to the stem (–13% vs. –2%). Below the stem bone loss was also higher (p = 0.01) for IS compared with FS (–6% vs. +1%) up to 1-year follow-up. Knee score improved similarly in both groups up to 5 years’ follow-up.Interpretation — Periprosthetic bone stress-shielding medial and posterior to the stem until 2 years, and tibial component migration at 5 years, was less for a finned compared with an I-shaped block stem design.
机译:背景与目的—全膝关节置换术胫骨组件上的茎提供了对剥离,剪切力和扭矩的机械抵抗力。我们将胫骨组件与鳍状茎(FS)和I型钢块茎(IS)进行了比较,以评估植入物迁移的差异。患者和方法—在一个患者盲的RCT中,有54名患者/膝盖(15名男性)患有膝关节骨关节炎平均年龄77岁(70-90)被随机分配为接受FS(n = 27)或IS(n = 27)的胫骨组件。经过5至7年的随访,使用RSA测量了植入物的迁移,使用DXA测量了假体周围的骨矿物质密度(BMD),并且外科医生报告了美国膝关节学会评分(AKSS)。结果—至少进行了5年的随访,IS(1.48mm,95%CI 0.81–2.16)的最大总点运动(MTPM)高于FS(0.85mm,CI 0.38–1.32)的胫骨组件(p = 0.04)。同样,IS(1.51˚,CI 0.78–2.24)的总旋转(TR)高于FS(0.81˚,CI 0.36-1.27)的(p = 0.03)。 IS的胫骨组件向外旋转0.50°(CI –0.06至1.06),而FS的胫骨组件内部旋转0.09°(CI –0.20至0.38)(p = 0.03)。与FS相比,在茎干内侧(–13%对–2%)和茎干后部(–13),IS随访2年的假体周围骨应力屏蔽更高(p <0.01) %与–2%)。在1年的随访中,IS下的骨干损失低于FS(–6%vs. + 1%),与IS相比更高(p = 0.01)。直到5年的随访,两组的膝关节评分均得到类似的改善。解释—与I相比,有鳍的胫骨假体的骨内侧和后侧直至2年,以及5年时胫骨组件的迁移较少。形块状阀杆设计。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号