Use of disposable skin staplers for bowel anastomosis to reduce laparotomy time in war.

机译:使用一次性皮肤吻合器进行肠吻合术以减少战争中的剖腹手术时间。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Laparotomy for penetrating wounds to the abdomen is demanding in terms of time, skill and resources. Any modification of existing techniques that will lessen these demands will be of benefit at surgery in forward areas in war. A previous paper (1) compared a method of small bowel anastomosis using disposable skin staplers with a two-layer handsewn anastomosis using fresh pig ileum. The stapled method was both significantly faster to perform and mechanically superior. In two further studies on a total of 12 pigs the stapled method has been compared with a single-layer and a double-layer handsewn small bowel anastomosis. All 12 pigs recovered from laparotomy without complication. Construction times were recorded. The quality of healing of the anastomoses was assessed by clinical observation, post-mortem and histological examination, and tensiometry. The skill required to perform the stapled anastomoses was estimated subjectively. The stapled technique was consistently faster than the handsewn methods. A Kolmogorov two-sample test showed an improvement in times when comparing the stapled method with the single layer, with a significance of P = 0.05. An improvement was also seen when the stapled method was compared with the double layer, with a significance of P = 0.01. There was no statistically significant difference between the construction times for the two handsewn methods. There was no evidence of anastomotic failure or haematoma at post-mortem and no adverse reaction to the metal staples. No features were identified on histology to indicate impaired healing with the stapled method. Tensiometry of the anastomoses showed that the stapled anastomosis is as mechanically reliable as the handsewn anastomosis.(ABSTRACT TRUNCATED AT 250 WORDS)
机译:在时间,技能和资源方面要求开腹手术以将伤口穿透到腹部。对现有技术的任何修改都会减少这些需求,这将有利于战争前沿地区的外科手术。先前的一篇论文(1)比较了使用一次性皮肤吻合器进行小肠吻合的方法与使用新鲜猪回肠进行两层手缝吻合的方法。装订方法不仅执行速度显着提高,而且在机械上也非常出色。在总共12头猪的两项进一步研究中,将装钉方法与单层和双层手缝小肠吻合术进行了比较。所有12头猪均从开腹手术中恢复,没有并发症。记录施工时间。通过临床观察,验尸和组织学检查以及张力测定法评估吻合口的愈合质量。主观评估吻合钉吻合术所需的技能。装订技术始终比手工缝制方法快。 Kolmogorov两样本测试显示,将装订方法与单层方法进行比较时,时间得到了改善,显着性P = 0.05。当将钉书方法与双层纸进行比较时,也看到了改进,其显着性为P = 0.01。两种手缝法的构建时间之间没有统计学上的显着差异。验尸后没有吻合失败或血肿的迹象,对金属钉书钉也没有不良反应。在组织学上未发现任何特征以表明钉合方法愈合不良。吻合器的张力测定法显示,吻合吻合器与手缝吻合器的机械可靠性相同。(摘要截断为250个字)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号