摘要

This report describes a comparison of the Behringwerke antistreptolysin O (ASO) latex screening test with the ASO hemolytic test. Agreement between the two tests was poor when Difco streptolysin O (SLO) reagent was employed in the hemolytic test; approximately 34% of the sera with ASO titers in the normal range of the hemolytic test gave false-positive latex test reactions. However, the percentage of false-positive latex test reactions was only 5% when Behringwerke SLO reagent was used in the hemolytic test. An assay of the Difco and Behringwerke SLO reagents against an ASO standard indicated that the Difco SLO reagent was more potent than the Behringwerke SLO reagent. The lack of agreement between the Behringwerke latex test and the hemolytic test using Difco SLO reagent is attributed to the potency of the SLO reagents.
机译:该报告描述了Behringwerke抗链球菌溶血素O(ASO)乳胶筛查试验与ASO溶血试验的比较。当溶血试验中使用Difco链球菌溶血素O(SLO)试剂时,两个试验之间的一致性差。在溶血试验正常范围内,约有34%的具有ASO滴度的血清产生假阳性乳胶试验反应。但是,在溶血测试中使用Behringwerke SLO试剂时,假阳性乳胶测试反应的百分比仅为5%。根据ASO标准对Difco和Behringwerke SLO试剂进行的分析表明,Difco SLO试剂比Behringwerke SLO试剂更有效。 Behringwerke乳胶测试与使用Difco SLO试剂的溶血测试之间缺乏一致性是由于SLO试剂的效力所致。