摘要

This study presents for the first time a new composite of carbon paste (CP), single-walled carbon nanotubes (SWCNTs) and Nd2O3 (NdOX). This versatile composite (NdOX-SWCNT/CPE) was applied to the oxidation of paracetamol (PCM). The newly formed surface was characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). The results showed greater conductivity and a higher surface area for the composite than those of the carbon paste alone. Moreover, the anodic peak currents for PCM increased from 1.6 to 3.6 µA with CPE and NdOX-SWCNT/CPE, indicating an increase of nearly 51.0% for the anodic peak current. On the other hand, the anodic peak potentials shifted from 0.67 to 0.57 V. The detection limits were 0.05 µmol/L with NdOX-SWCNT/CPE and 0.50 µmol/L with SWCNT/CPE. The relative standard deviations (RSDs) were 1.5% (n = 7). The accuracy and interference of the methods were evaluated with a urine chemistry control spiked with known quantities of PCM, uric acid, dopamine, ascorbic acid, caffeine, acetylsalicylic acid, tartrazine, sunset yellow, allure red, rutin, morin and metal ions. Finally, the novelty and usefulness of the composite were evaluated to quantify PCM in pharmaceutical dosage forms such as tablets, powders and syrups for children.
机译:这项研究首次提出了碳糊(CP),单壁碳纳米管(SWCNT)和Nd2O3(NdOX)的新型复合材料。将该多功能复合材料(NdOX-SWCNT / CPE)应用于对乙酰氨基酚(PCM)的氧化。通过扫描电子显微镜(SEM),电化学阻抗谱(EIS)和循环伏安法(CV)对新形成的表面进行表征。结果表明,与单独的碳糊相比,复合材料具有更高的电导率和更大的表面积。此外,使用CPE和NdOX-SWCNT / CPE时,PCM的阳极峰值电流从1.6µA增加到3.6µA,表明阳极峰值电流增加了近51.0%。另一方面,阳极峰电位从0.67变为0.57 V,NdOX-SWCNT / CPE的检测限为0.05 µmol / L,SWCNT / CPE的检测限为0.50 µmol / L。相对标准偏差(RSD)为1.5%(n = 7)。该方法的准确性和干扰性是通过添加了已知量的PCM,尿酸,多巴胺,抗坏血酸,咖啡因,乙酰水杨酸,酒石黄,日落黄,诱惑红,芦丁,香mo和金属离子的尿液化学控制来评估的。最后,对复合材料的新颖性和实用性进行了评估,以量化药物剂型(如儿童片剂,散剂和糖浆剂)中的PCM。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号