首页> 美国卫生研究院文献>Bioinorganic Chemistry and Applications >The Effect of Hydrofluoric Acid Surface Treatment on the Cyclic Fatigue Resistance of K3 NiTi Instruments
【2h】

The Effect of Hydrofluoric Acid Surface Treatment on the Cyclic Fatigue Resistance of K3 NiTi Instruments

机译:氢氟酸表面处理对K3 NiTi仪器的循环疲劳强度的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to investigate the effect of 50% hydrofluoric acid (HF) surface treatment on the cyclic fatigue resistance (CFR) of K3 NiTi instruments. Twenty as-received and twenty HF-treated K3 NiTi instruments were compared in CFR. The surface texture and fracture surface of two instrument groups were examined with a scanning electron microscope (SEM). Additionally, any change of Ni and Ti composition from both instrument groups was investigated using energy dispersive spectrometry. The results were analyzed with t-test. The HF-treated K3 group showed statistically higher cyclic fatigue resistance than as-received K3 group (P < 0.05). HF-treated K3 instruments showed smoother and rounded surface compared to as-received K3 under SEM observation. The fracture surfaces of both groups showed typical patterns of cyclic fatigue fracture. There was no difference in surface Ni and Ti composition between two groups. HF treatment of K3 instruments smoothed the file surface and increased the cyclic fatigue resistance, while it had no effect on surface ion composition and the file fracture pattern.
机译:这项研究的目的是研究50%氢氟酸(HF)表面处理对K3 NiTi仪器的抗循环疲劳性(CFR)的影响。在CFR中比较了20台接收到的和20台经过HF处理的K3 NiTi仪器。用扫描电子显微镜(SEM)检查两个器械组的表面纹理和断裂表面。另外,使用能量色散光谱法研究了两个仪器组中镍和钛成分的任何变化。用t检验分析结果。经统计学处理的K3组比经K3处理的组表现出更高的循环疲劳强度(P <0.05)。经HF处理的K3仪器与通过SEM观察得到的K3相比,表面更光滑且呈圆形。两组的断裂表面均表现出典型的循环疲劳断裂模式。两组之间的表面Ni和Ti组成没有差异。 K3仪器的HF处理使锉刀表面变得光滑,并提高了耐循环疲劳性,但对表面离子组成和锉刀断裂模式没有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号