首页> 美国卫生研究院文献>Biophysical Journal >Weak Interactions Govern the Viscosity of Concentrated Antibody Solutions: High-Throughput Analysis Using the Diffusion Interaction Parameter
【2h】

Weak Interactions Govern the Viscosity of Concentrated Antibody Solutions: High-Throughput Analysis Using the Diffusion Interaction Parameter

机译:弱相互作用控制浓缩抗体溶液的粘度:使用扩散相互作用参数的高通量分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Weak protein-protein interactions are thought to modulate the viscoelastic properties of concentrated antibody solutions. Predicting the viscoelastic behavior of concentrated antibodies from their dilute solution behavior is of significant interest and remains a challenge. Here, we show that the diffusion interaction parameter (kD), a component of the osmotic second virial coefficient (B2) that is amenable to high-throughput measurement in dilute solutions, correlates well with the viscosity of concentrated monoclonal antibody (mAb) solutions. We measured the kD of 29 different mAbs (IgG1 and IgG4) in four different solvent conditions (low and high ion normality) and found a linear dependence between kD and the exponential coefficient that describes the viscosity concentration profiles (|R| ≥ 0.9). Through experimentally measured effective charge measurements, under low ion normality where the electroviscous effect can dominate, we show that the mAb solution viscosity is poorly correlated with the mAb net charge (|R| ≤ 0.6). With this large data set, our results provide compelling evidence in support of weak intermolecular interactions, in contrast to the notion that the electroviscous effect is important in governing the viscoelastic behavior of concentrated mAb solutions. Our approach is particularly applicable as a screening tool for selecting mAbs with desirable viscosity properties early during lead candidate selection.
机译:弱的蛋白质间相互作用被认为可调节浓缩抗体溶液的粘弹性质。从稀释溶液的行为预测浓缩抗体的粘弹性行为具有重大意义,并且仍然是一个挑战。在这里,我们显示了扩散相互作用参数(kD),它是适于在稀溶液中进行高通量测量的渗透性第二病毒系数(B2)的组成部分,与浓缩单克隆抗体(mAb)溶液的粘度密切相关。我们在四种不同的溶剂条件(低和高离子正态性)下测量了29种不同mAb(IgG1和IgG4)的kD,发现kD与描述粘度浓度曲线(| R |≥0.9)的指数系数之间存在线性关系。通过实验测量的有效电荷测量,在低电正态性(电粘性可以控制)的情况下,我们表明mAb溶液的粘度与mAb净电荷的相关性很低(| R |≤0.6)。有了这个庞大的数据集,我们的结果为支持弱分子间相互作用提供了令人信服的证据,与之相反的观点是,电粘滞效应对于控制浓缩mAb溶液的粘弹性行为很重要。我们的方法特别适合用作筛选工具,用于在潜在候选人的早期选择中选择具有所需粘度特性的mAb。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号