首页> 美国卫生研究院文献>Chronic Respiratory Disease >Comparison of two- and six-minute walk tests in detecting oxygen desaturation in patients with severe chronic obstructive pulmonary disease — A randomized crossover trial
【2h】

Comparison of two- and six-minute walk tests in detecting oxygen desaturation in patients with severe chronic obstructive pulmonary disease — A randomized crossover trial

机译:在重度慢性阻塞性肺疾病患者中进行2分钟和6分钟步行测试以检测氧饱和度的比较-一项随机交叉试验

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The two-minute walk test (2MWT) is less well validated than the well-known six-minute walk test (6MWT) as a field walking test in patients with chronic obstructive pulmonary disease (COPD). The primary objective of this study was to compare the accuracy of the 2MWT to the 6MWT in detecting exercise-induced oxygen desaturation in patients with severe COPD. Twenty-six patients with COPD (age: 61 ± 10 years, forced expired volume in one second: 37 ± 10%) that were normoxemic at rest performed a 2MWT and a 6MWT under normal ambient conditions on two consecutive days in random order. Oxygen saturation, total walking distance, heart rate, breathing frequency, dyspnea, and leg fatigue were evaluated. Average walking distances were 150 m (95% confidence interval (95% CI): 134–165 m) and 397 m (95% CI: 347–447 m) for the 2MWT and 6MWT, respectively (r = 0.80, p < 0.0001). The difference in minimum oxygen saturation during the 2MWT (83%, 95% CI: 81–86%) and 6MWT (mean 82%, 95% CI: 80–84%) was not statistically different and the data strongly correlated between the groups (r = 0.81, p < 0.0001). Other measurements from the 6MWT, including heart rate, breathing rate, and levels of perceived exertion were also comparable in 2MWT. The 2MWT showed comparable validity in detecting exercise-induced oxygen desaturation in patients with severe COPD compared to the 6MWT.
机译:两分钟步行测试(2MWT)的有效性不如众所周知的六分钟步行测试(6MWT)作为慢性阻塞性肺疾病(COPD)患者的现场步行测试。这项研究的主要目的是比较2MWT和6MWT在检测重度COPD患者运动引起的氧饱和度方面的准确性。在正常环境下,正常休息的26名COPD患者(年龄:61±10岁,在一秒钟内被迫过期的体积:37±10%)在正常环境下连续两天随机执行2MWT和6MWT。评估氧饱和度,总步行距离,心率,呼吸频率,呼吸困难和腿部疲劳。 2MWT和6MWT的平均步行距离分别为150 m(95%置信区间(95%CI):134–165 m)和397 m(95%CI:347–447 m)(r = 0.80,p <0.0001 )。 2MWT(83%,95%CI:81–86%)和6MWT(平均82%,95%CI:80–84%)期间的最低氧饱和度差异无统计学差异,各组之间的数据高度相关(r = 0.81,p <0.0001)。 6MWT的其他测量值(包括心率,呼吸频率和感知的劳累水平)在2MWT中也相当。与6MWT相比,2MWT在检测重度COPD患者运动引起的氧饱和度方面显示出相当的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号