首页> 美国卫生研究院文献>Journal of Ultrasonography >Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
【2h】

Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults

机译:下腔静脉/主动脉直径指数在体液状况评估中的比较研究–由一组经验丰富和经验不足的检查者对一组年轻人进行的测量结果的比较研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta diameter index in a sonographic hydration assessment. The study enrolled 50 young students at the age of 19–26 (the median age was 22.95) including 27 women and 23 men. The volunteers were examined in the supine position with GE Logiq 7 system and a convex transducer with the frequency of 2–5 MHz. The measurements were performed in the longitudinal and transverse planes by two inexperienced examiners – the authors of this paper, following a four-hour training conducted by an experienced sonographer. The longitudinal values of the inferior vena cava/aorta diameter index obtained in this study were similar to those found in the literature. The reference value for the inferior vena cava/aorta index determined by Kosiak et al., which constituted 1.2 ± 2 SD, for SD = 0.17, was similar to the values obtained by the authors of this paper which equaled 1.2286 ± 2 SD, for SD = 0.2. The article presented below proves that measuring the inferior vena cava/aorta diameter index is not a complex examination and it may be performed by physicians with no sonographic experience. Furthermore, the paper demonstrates that the inferior vena cava/aorta diameter index measured in the transverse plane is similar to the inferior vena cava/aorta diameter index determined in the longitudinal plane. Thus, both measurements may be used interchangeably to assess the hydration status of patients.
机译:体液状态的评估是临床实践中最具挑战性的任务之一。尽管有许多方法可以评估患者的体液状况,但是在现代医学中,没有一种方法能够完全令人满意。在下面的文章中,我们在超声水化评估中根据下腔静脉/主动脉直径指数比较经验丰富和经验不足的检查员的测量结果。该研究招募了50名19-26岁的青年学生(中位年龄为22.95),其中包括27名女性和23名男性。使用GE Logiq 7系统和频率为2–5 MHz的凸形换能器对仰卧位的志愿者进行检查。测量是由两名缺乏经验的检查员在纵向和横向进行的–本文的作者是由经验丰富的超声检查师进行的四个小时培训。在这项研究中获得的下腔静脉/主动脉直径指数的纵向值与文献中的相似。由Kosiak等人确定的下腔静脉/主动脉指数的参考值为1.2±2 SD,SD = 0.17,类似于本文作者获得的等于1.2286±2 SD的参考值。 SD = 0.2。下面介绍的文章证明,测量下腔静脉/主动脉直径指数并不是一项复杂的检查,可以由没有超声检查经验的医生进行。此外,该论文证明了在横切面上测量的下腔静脉/主动脉直径指数与在纵切面上确定的下腔静脉/主动脉直径指数相似。因此,两种测量可以互换使用以评估患者的水合作用状况。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号