首页> 美国卫生研究院文献>Journal of Visualized Experiments : JoVE >Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
【2h】

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications

机译:微型固相萃取与LC-MS / MS检测法结合用于人体尿液中的3-硝基酪氨酸的临床应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Free 3-nitrotyrosine (3-NT) has been extensively used as a possible biomarker for oxidative stress. Increased levels of 3-NT have been reported in a wide variety of pathological conditions. However, existing methods lack the sufficient sensitivity and/or specificity necessary to measure the low endogenous level of 3-NT reliably and are too cumbersome for clinical applications. Hence, analytical improvement is urgently needed to accurately quantify the levels of 3-NT and verify the role of 3-NT in pathological conditions. This protocol presents the development of a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) detection combined with a miniaturized solid phase extraction (SPE) for the rapid and accurate measurement of 3-NT in human urine as a non-invasive biomarker for oxidative stress. SPE using a 96-well plate markedly simplified the process by combining sample cleanup and analyte enrichment without tedious derivatization and evaporation steps, reducing solvent consumption, waste disposal, risk of contamination and overall processing time. The employment of 25 mM ammonium acetate (NH4OAc) at pH 9 as the SPE elution solution substantially enhanced the selectivity. Mass spectrometry signal response was improved through adjustment of the multiple reaction monitoring (MRM) transitions. Use of 0.01% HCOOH as additive on a pentafluorophenyl (PFP) column (150 mm x 2.1 mm, 3 µm) improved signal response another 2.5-fold and shortened the overall run time to 7 min. A lower limit of quantitation (LLOQ) of 10 pg/mL (0.044 nM) was achieved, representing a significant sensitivity improvement over the reported assays. This simplified, rapid, selective and sensitive method allows two plates of urine samples (n = 192) to be processed in a 24 h time-period. Considering the markedly improved analytical performance, and non-invasive and inexpensive urine sampling, the proposed assay is beneficial for pre-clinical and clinical studies.
机译:游离3-硝基酪氨酸(3-NT)已被广泛用作氧化应激的可能生物标记。据报道,在各种病理状况下,3-NT的水平均升高。然而,现有方法缺乏可靠地测量3-NT的低内源性水平所需的足够的敏感性和/或特异性,并且对于临床应用而言太麻烦。因此,迫切需要进行分析改进以准确定量3-NT的水平并验证3-NT在病理条件下的作用。该协议提出了一种新型液相色谱串联质谱(LC-MS / MS)检测技术与微型固相萃取(SPE)技术相结合的技术,可快速,准确地测量人尿液中的3-NT作为非侵入性生物标志物用于氧化应激。使用96孔板的SPE通过组合样品净化和分析物富集而无需繁琐的衍生化和蒸发步骤,从而显着简化了过程,从而减少了溶剂消耗,废物处理,污染风险和整个处理时间。使用pH为9的25 mM乙酸铵(NH4OAc)作为SPE洗脱液,大大提高了选择性。通过调整多反应监测(MRM)跃迁可以改善质谱信号响应。在五氟苯基(PFP)色谱柱(150 mm x 2.1 mm,3 µm)上使用0.01%HCOOH作为添加剂可将信号响应提高2.5倍,并将总运行时间缩短至7分钟。达到了10 pg / mL(0.044 nM)的定量下限(LLOQ),与已报道的检测方法相比,灵敏度显着提高。这种简化,快速,选择性和灵敏的方法允许在24小时内处理两板尿液样品(n = 192)。考虑到分析性能的显着改善以及无创且廉价的尿液采样,建议的测定方法对临床前和临床研究是有益的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号