首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Ambulatory Evaluation of ECG Signals Obtained Using Washable Textile-Based Electrodes Made with Chemically Modified PEDOT:PSS
【2h】

Ambulatory Evaluation of ECG Signals Obtained Using Washable Textile-Based Electrodes Made with Chemically Modified PEDOT:PSS

机译:使用经过化学修饰的PEDOT:PSS制成的可洗纺织品基电极获得的心电信号动态评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A development of washable PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) polyamide textile-based electrodes is an interesting alternative to the traditional Ag/AgCl disposable electrodes, usually used in clinical practice, helping to improve medical assessment and treatment before apparition or progress of patients’ cardiovascular symptoms. This study was conducted in order to determine whether physical properties of PEDOT:PSS had a significant impact on the coated electrode’s electrocardiogram (ECG) signal quality, particularly after 50 washing cycles in a domestic laundry machine. Tests performed, included the comparison of two PEDOT:PSS solutions, in term of viscosity with emphasis on wetting tests, including surface tension and contact angle measurements. In addition, polyamide textile fabrics were used as substrate to make thirty electrodes and to characterize the amount of PEDOT:PSS absorbed as a function of time. The results showed that surface tension of PEDOT:PSS had a significant impact on the wetting of polyamide textile fabric and consequently on the absorbed amount. In fact, lower values of surface tension of the solution lead to low values contact angles between PEDOT:PSS and textile fabric (good wettability). Before washing, no significant difference has been observed among signal-to-noise ratios measured (SNR) for coated electrodes by the two PEDOT:PSS solutions. However, after 50 washing cycles, SNR decreased strongly for electrodes coated by the solution that had low viscosity, since it contained less solid contents. That was confirmed by scanning electron microscopy images (SEM) and also by analyzing the color change of electrodes based on the calculation of CIELAB color space coordinates. Moreover, spectral power density of recorded ECG signals has been computed and presented. All cardiac waves were still visible in the ECG signals after 50 washing cycles. Furthermore, an experienced cardiologist considered that all the ECG signals acquired were acceptable. Accordingly, our newly developed polyamide textile-based electrodes seem to be suitable for long-term monitoring. The study also provided new insights into the better choice of PEDOT:PSS formulation as a function of a specific process in order to manufacture cheaper electrodes faster.
机译:可水洗的PEDOT:PSS(聚(3,4-乙撑二氧噻吩)聚苯乙烯磺酸盐)聚酰胺纺织电极的开发是传统Ag / AgCl一次性电极的一种有趣的替代品,通常在临床实践中使用,有助于改善医学评估和治疗在患者出现心血管症状之前或出现之前。进行这项研究是为了确定PEDOT:PSS的物理性质是否对涂覆电极的心电图(ECG)信号质量有显着影响,尤其是在家用洗衣机中进行50次洗涤后。进行的测试包括比较两种PEDOT:PSS溶液的粘度,重点是润湿测试,包括表面张力和接触角测量。另外,聚酰胺纺织物被用作基底以制造三十个电极并表征作为时间的函数吸收的PEDOT:PSS的量。结果表明,PEDOT:PSS的表面张力对聚酰胺织物的润湿性有很大影响,因此对吸收量也有显着影响。实际上,溶液表面张力的值较低会导致PEDOT:PSS与织物之间的接触角值较小(良好的润湿性)。清洗之前,两种PEDOT:PSS溶液在涂覆电极的信噪比(SNR)之间没有发现显着差异。但是,经过50个洗涤周期后,由于溶液中的固体成分较少,因此涂有低粘度溶液的电极的SNR大大降低。通过扫描电子显微镜图像(SEM)并通过基于CIELAB颜色空间坐标的计算分析电极的颜色变化,可以证实这一点。此外,已记录并记录了记录的ECG信号的频谱功率密度。经过50个洗涤周期后,所有心电波仍在ECG信号中可见。此外,一位经验丰富的心脏病学家认为所获得的所有ECG信号都是可以接受的。因此,我们新开发的聚酰胺纺织品基电极似乎适合于长期监测。该研究还提供了针对特定过程的PEDOT:PSS配方更好选择的新见解,以便更快地制造更便宜的电极。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号