首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study
【2h】

Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study

机译:使用无线惯性运动捕获设备评估肩膀运动范围的有效性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

(1) Background: Measuring joint range of motion has traditionally occurred with a universal goniometer or expensive laboratory based kinematic analysis systems. Technological advances in wearable inertial measurement units (IMU) enables limb motion to be measured with a small portable electronic device. This paper aims to validate an IMU, the ‘Biokin’, for measuring shoulder range of motion in healthy adults; (2) Methods: Thirty participants completed four shoulder movements (forward flexion, abduction, and internal and external rotation) on each shoulder. Each movement was assessed with a goniometer and the IMU by two testers independently. The extent of agreement between each tester’s goniometer and IMU measurements was assessed with intra-class correlation coefficients (ICC) and Bland-Altman 95% limits of agreement (LOA). Secondary analysis compared agreement between tester’s goniometer or IMU measurements (inter-rater reliability) using ICC’s and LOA; (3) Results: Goniometer and IMU measurements for all movements showed high levels of agreement when taken by the same tester; ICCs > 0.90 and LOAs < ±5 degrees. Inter-rater reliability was lower; ICCs ranged between 0.71 to 0.89 and LOAs were outside a prior defined acceptable LOAs (i.e., > ±5 degrees); (4) Conclusions: The current study provides preliminary evidence of the concurrent validity of the Biokin IMU for assessing shoulder movements, but only when a single tester took measurements. Further testing of the Biokin’s psychometric properties is required before it can be confidently used in routine clinical practice and research settings.
机译:(1)背景:传统上使用通用的测角仪或昂贵的基于实验室的运动学分析系统来测量关节的运动范围。穿戴式惯性测量单元(IMU)的技术进步使得可以用小型便携式电子设备测量肢体运动。本文旨在验证一种IMU(“生物素”),以测量健康成年人的肩膀运动范围。 (2)方法:30名参与者在每个肩膀上完成了4次肩部运动(向前弯曲,外展以及内外旋转)。每个运动均由两名测试人员分别通过测角计和IMU进行评估。使用类内相关系数(ICC)和Bland-Altman 95%一致性限制(LOA)评估每个测试人员的测角仪和IMU测量值之间的一致性程度。二级分析比较了使用ICC和LOA的测试仪的测角仪或IMU测量值(评定者之间的可靠性)之间的一致性; (3)结果:当使用同一测试仪进行测量时,对所有运动的测角仪和IMU测量显示出很高的一致性; ICC> 0.90,LOA <±5度。评价者间的可靠性较低; ICC介于0.71至0.89之间,LOA超出了预先定义的可接受LOA(即>±5度); (4)结论:本研究为Biokin IMU评估肩部运动的同时有效性提供了初步证据,但仅在单个测试人员进行测量时才有效。必须先对Biokin的心理测量特性进行进一步测试,然后才能将其确信地用于常规临床实践和研究环境。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号