首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Experimental Study on Active Interface Debonding Detection for Rectangular Concrete-Filled Steel Tubes with Surface Wave Measurement
【2h】

Experimental Study on Active Interface Debonding Detection for Rectangular Concrete-Filled Steel Tubes with Surface Wave Measurement

机译:矩形钢管混凝土主动界面剥离检测的表面波实验研究。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Concrete-filled steel tube (CFST) members have been widely employed as major structural members carrying axial or vertical loads and the interface bond condition between steel tube and concrete core plays key roles in ensuring the confinement effect of steel tube on concrete core. An effective interface debonding defect detection approach for CFSTs is critical. In this paper, an active interface debonding detection approach using surface wave measurement with a piezoelectric lead zirconate titanate (PZT) patch as sensor mounted on the outer surface of the CFST member excited with a PZT actuator mounted on the identical surface is proposed in order to avoid embedding PZT-based smart aggregates (SAs) in concrete core. In order to validate the feasibility of the proposed approach and to investigate the effect of interface debonding defect on the surface wave measurement, two rectangular CFST specimens with different degrees of interface debonding defects on three internal surfaces are designed and experimentally studied. Surface stress waves excited by the PZT actuator and propagating along the steel tube of the specimens are measured by the PZT sensors with a pitch and catch pattern. Results show that the surface-mounted PZT sensor measurement is sensitive to the existence of interface debonding defect and the interface debonding defect leads to the increase in the voltage amplitude of surface wave measurement. A damage index defined with the surface wave measurement has a linear relationship with the heights of the interface debonding defects.
机译:钢管混凝土(CFST)构件已广泛用作承载轴向或垂直载荷的主要结构构件,钢管与混凝土芯之间的界面粘结条件在确保钢管对混凝土芯的约束效果方面起着关键作用。对于CFST,有效的界面分离缺陷检测方法至关重要。在本文中,提出了一种使用表面波测量的有源界面剥离检测方法,该方法以压电锆钛酸铅钛酸盐(PZT)贴片作为传感器安装在CFST构件外表面上,并由安装在同一表面上的PZT执行器激励。避免将基于PZT的智能聚合(SA)嵌入到混凝土核心中。为了验证该方法的可行性并研究界面剥离缺陷对表面波测量的影响,设计并实验研究了两个矩形的CFST标本,它们在三个内表面上具有不同程度的界面剥离缺陷。由PZT执行器激发并沿试样钢管传播的表面应力波由PZT传感器以俯仰和捕获模式测量。结果表明,表面贴装的PZT传感器测量对界面剥离缺陷的存在很敏感,界面剥离缺陷导致表面波测量的电压幅值增加。由表面波测量定义的损伤指数与界面剥离缺陷的高度成线性关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号