A rapid method and instrumentation for quantification of immunochromatographic tests (ICT) are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG) present in urine. The test format was a sandwich assay using two distinct monoclonal antibodies directed against hCG. The first anti-hCG antibody was labeled with superparamagnetic particles whereas the second was immobilized as a narrow detection zone on a porous membrane. The human urine sample was mixed with superparamagnetic particles coated with the first anti-hCG antibody, and the mixture was allowed to migrate past the detection zone containing the second anti-hCG antibody. Capillary forces facilitated migration of the immune complexes along the porous membrane. The amount of superparamagnetic particle-labelled monoclonal anti-hCG bound to the detection zone was directly proportional to the amount of hCG present in the sample as detected by measuring magnetization in the detector coil. The method had a practical detection limit of 20 U/l (54 nM) of hCG per 5 μl of human urine and a linear range of three decades from 20 U/l to 10 000 U/l. In addition, the analysis was completed within less than 10 minutes. Thus, the test format should be suitable for fast detection and monitoring of a large variety of clinically important parameters and analytes.
机译:描述了一种定量免疫色谱测试(ICT)的快速方法和仪器。通过测量尿液中人绒毛膜促性腺激素(hCG)的含量证明了该方法的原理和性能。测试形式是使用两种针对hCG的独特单克隆抗体进行的夹心测定。第一种抗hCG抗体用超顺磁性颗粒标记,而第二种则被固定为多孔膜上的狭窄检测区。将人类尿液样品与涂有第一抗hCG抗体的超顺磁性颗粒混合,然后使混合物迁移通过含有第二抗hCG抗体的检测区。毛细作用力促进了免疫复合物沿着多孔膜的迁移。结合到检测区的超顺磁性颗粒标记的单克隆抗hCG的量与样品中存在的hCG的量成正比,这是通过测量检测器线圈中的磁化强度来检测的。该方法的实际检出限为每5微升人类尿液20 h / l(54 nM)hCG,线性范围为20 U / l至10000 U / l,为三十年。此外,分析在不到10分钟的时间内完成。因此,测试格式应适合于快速检测和监测多种临床上重要的参数和分析物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号