Post-implantation Deformation of Titanium Rod and Cobalt Chrome Rod in Adolescent Idiopathic Scoliosis

机译:青少年特发性脊柱侧弯钛棒和钴铬棒的植入后变形

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Introduction: Post-implantation rod deformation is anticipated in scoliosis surgery but the difference in rod deformation between titanium and cobalt chrome rod has not been elucidated. This study aims to compare the difference in rod deformation between two groups.>Materials and Methods: Twenty-one adolescent idiopathic scoliosis (AIS) patients were recruited from a single center. The over-contoured concave rods were traced prior to insertion. Post-operative sagittal rod shape was determined from lateral radiographs. Rod deformation was determined using maximal rod deflection and angle of the tangents to rod end points. The differences between pre- and post-operative rod contour were analysed statistically. Rod deformation and thoracic kyphosis between two types of implants were analysed.>Results: Both rods exhibited significant change of rod angle and deflection post-operatively. Curvature of the titanium rod and cobalt chrome rod decreased from 60.5° to 37°, and 51° to 28° respectively. Deflection of titanium rod and cobalt chrome rod reduced from 28mm to 23.5mm and 30mm to 17mm respectively. There was no significant difference between titanium and cobalt chrome groups with regard to rod angle (p=0.173) and deflection (p=0.654). Thoracic kyphosis was increased from 20° to 26° in titanium group but a reduction from 25° to 23° was noticed in cobalt chrome group, but these findings were not statistically significant.>Conclusion: There was no statistical difference in rod deformation between the two groups. Thus, the use of titanium rod in correction of sagittal profile is not inferior in outcome compared with cobalt chrome but with lower cost.
机译:>简介:在脊柱侧弯手术中预期植入后杆变形,但钛和钴铬杆之间杆变形的差异尚未阐明。本研究旨在比较两组患者棒变形的差异。>材料与方法:从一个中心招募了21名青少年特发性脊柱侧弯(AIS)患者。在插入之前先绘制轮廓过大的凹棒。术后矢状杆的形状由侧面X线照片确定。使用最大杆挠度和切线与杆终点的角度确定杆变形。术前和术后杆轮廓之间的差异进行了统计分析。分析了两种植入物之间的杆变形和胸椎后凸畸形。>结果:术后两根杆均出现杆角度和偏转的显着变化。钛棒和钴铬棒的曲率分别从60.5°降低到37°,从51°降低到28°。钛棒和钴铬棒的挠度分别从28mm减小到23.5mm,从30mm减小到17mm。钛和钴铬基团在杆角(p = 0.173)和挠度(p = 0.654)方面没有显着差异。钛组的胸椎后凸畸形从20°升高到26°,钴铬组的胸椎后凸从25°降低到23°,但这些发现没有统计学意义。>结论:两组之间的杆变形差异。因此,与钴铬合金相比,钛棒在矢状面矫正中的使用效果并不差,但成本较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号