首页> 美国卫生研究院文献>European Spine Journal >Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing
【2h】

Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing

机译:初步研究:脊柱轮的可靠性。一种用于测量坐姿和站立姿的脊柱姿势的新颖设备

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Postural re-education is an integral part of physiotherapy management in patients with back pain. Although the link between posture and back pain is largely unknown, postural re-education is performed on the premise of optimizing spinal alignment to minimize stresses on the passive structures of the spine, to facilitate optimal muscular support and thus to prevent possible damage and further pain. A reliable and clinically meaningful measurement of spinal postures to monitor such interventions remains challenging. This study evaluated within-day (intra-tester, inter-tester) and between-day (test–retest) reliability of a novel spinal wheel device measuring thoracic and lumbar postures during sitting and standing. 17 healthy volunteers (age 39.5 ± 5.4, BMI 25 ± 9.2; 9 males) were measured three times, by three testers, on two separate occasions (1 week apart). The angular change between C7 and T12 and between T12 and S1 provided thoracic and lumbar curvatures, respectively. Intra-class correlation coefficient (ICC) with 95% confidence intervals and typical error were calculated. Excellent reliability was demonstrated with intra-tester ICCs between 0.947 and 0.980 and typical error between 1.7° and 3.7° and inter-tester ICCs between 0.949 and 0.986 and typical error between 2.0° and 4.7°. Test–retest reliability was high with ICCs 0.719–0.908 and typical error between 4.0° and 7.4°. In conclusion, the spinal wheel demonstrated excellent within-day and high between-day reliability. The device may be used in conjunction with 2D camcorder to provide clinically useful visual evaluation of postures for assessment, intervention monitoring, and feedback during postural re-education.
机译:姿势再教育是腰痛患者理疗管理中不可或缺的一部分。尽管姿势和背部疼痛之间的联系尚不清楚,但在优化脊柱对齐的前提下进行姿势再教育,以最大程度地减少脊柱被动结构上的压力,以促进最佳的肌肉支撑,从而防止可能的伤害和进一步的疼痛。对脊柱姿势进行可靠且临床上有意义的测量以监测此类干预措施仍然具有挑战性。这项研究评估了一种新型的脊轮器械在坐着和站着期间测量胸和腰部姿势的日内(测试者内,测试者之间)和日间(测试-重新测试)可靠性。 17名健康志愿者(39.5±5.4岁,BMI 25±9.2; 9名男性)在两次单独的场合(相隔1周)被三名测试人员测量了三次。 C7与T12之间以及T12与S1之间的角度变化分别提供了胸曲和腰曲。计算了具有95%置信区间和典型误差的类内相关系数(ICC)。测试器内部ICC在0.947至0.980之间,典型误差在1.7°至3.7°之间,测试间ICC在0.949至0.986之间,典型误差在2.0°至4.7°之间,显示了出色的可靠性。 ICC为0.719-0.908时,重测可靠性很高,典型误差在4.0°至7.4°之间。总之,脊柱轮在日间具有出色的可靠性,并具有很高的日间可靠性。该设备可以与2D摄录一体机结合使用,以提供临床上有用的姿势视觉评估,以进行姿势再教育期间的评估,干预监测和反馈。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号