>Background: The objective of this study was to compare the mechanical performance of 4 different constructs for fixation of oblique scaphoid fractures. >Methods: Twenty-eight synthetic scaphoids underwent an oblique osteotomy along the dorsal sulcus. Each was randomly assigned to fixation by 1 of 4 methods: two 1.5-mm headless compression screws, one 2.2-mm screw, one 3-mm screw, or a 1.5-mm volar variable-angle plate. After fixation, scaphoids were potted at a 45° angle and loaded at the distal pole by a hydraulically driven mechanical testing system plunger until the fixation failed. Excursion and load were measured with a differential transformer and load cell, respectively. From these data, the stiffness, load-to-failure, and maximum displacement of each construct were calculated. >Results: The 2.2-mm screw demonstrated the highest stiffness and the two 1.5-mm screws had the lowest. However, there were no significant differences among the fixation methods in terms of stiffness. Both 2.2- and 3-mm screw constructs had significantly higher loads-to-failure than two 1.5-mm screws. The maximum load for the plate approached, but did not achieve, statistical significance compared with the 1.5-mm screws. There was no significant difference among constructs in displacement. >Conclusions: All constructs demonstrated similar mechanical properties that may provide sufficient stability for effective clinical use. Given their significantly higher loads-to-failure, a 2.2- or 3-mm screw may be superior to two 1.5-mm screws for fixation of unstable scaphoid fractures. The volar plate did not have superior mechanical characteristics to the compression screws.
机译:>背景:本研究的目的是比较4种不同构造的固定舟状斜舟骨骨折的力学性能。 >方法: 28个合成舟骨沿背沟进行了斜截骨术。每种方法均通过以下4种方法之一随机分配:2个1.5毫米无头压缩螺钉,1个2.2毫米螺钉,1个3毫米螺钉或1.5毫米掌侧可变角度钢板。固定后,将舟骨以45°的角度盆栽,并通过液压驱动的机械测试系统柱塞将其装在远端,直到固定失败。偏移和负载分别使用差动变压器和称重传感器进行测量。根据这些数据,计算出每个结构的刚度,破坏载荷和最大位移。 >结果:2.2毫米螺钉的刚度最高,而两颗1.5毫米螺钉的刚度最低。但是,固定方法之间在硬度方面没有显着差异。 2.2毫米和3毫米螺钉构造的故障载荷均明显高于两个1.5毫米螺钉。与1.5毫米螺钉相比,该板的最大载荷接近但未达到统计显着性。移位之间的构造之间没有显着差异。 >结论:所有构建体均显示出相似的机械性能,可为有效的临床使用提供足够的稳定性。鉴于它们的破坏载荷要高得多,在固定不稳定的舟骨骨折时,使用2.2毫米或3毫米螺钉可能要优于两个1.5毫米螺钉。掌骨板没有压缩螺钉优越的机械特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号