摘要

AC corrosion has been considere d as a threat to the corrosion of buried pipelines. Effects of sulfate-reducing bacteria (SRB) and alternating current (AC) on corrosion of X80 pipeline steel in soil-extract solution were investigated by electrochemical and surface analysis techniques. AC current can inhibit the growth of planktonic and sessile SRB. The corrosion current density of steel with 10 mA/cm2 AC current is about nine times bigger than that without AC current. Corrosion morphology changes from small pitting to large pitting holes with increasing AC current density. Corrosion of steel with SRB and AC current is controlled by both active dissolution of iron and film degradation.
机译:交流腐蚀被认为是对地下管道腐蚀的威胁。通过电化学和表面分析技术,研究了硫酸盐还原细菌(SRB)和交流电(AC)对X80管线钢在土壤提取液中腐蚀的影响。交流电流可以抑制浮游性和无柄SRB的生长。交流电流为10 mA / cm 2 的钢的腐蚀电流密度约为不交流电流的腐蚀电流密度的九倍。随着交流电流密度的增加,腐蚀形态从小蚀孔变为大蚀孔。钢的SRB和交流电流对钢的腐蚀可通过铁的主动溶解和膜降解来控制。