This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fast, stable, and linear response for KTF over the concentration range of 10−7 to 10−2 mol L−1. The electrodes show Nernstian slope value of 52.51 ± 0.20 and 51.51 ± 0.25 mV decade−1 for CPE and PVC membrane electrodes at 30°C, respectively. The potential is nearly stable over the pH range 3.0–6.0 and 2.0–7.0 for CPE and PVC membrane electrodes, respectively. Selectivity coefficient values towards different inorganic cations, sugars, and amino acids reflect high selectivity of the prepared electrodes. The electrodes responses at different temperatures were also studied, and long operational lifetime of 12 and 5 weeks for CPE and PVC membrane electrodes, respectively, were found. These are used for determination of ketotifen fumarate using potentiometric titration, calibration, and standard addition methods in pure samples, its pharmaceutical preparations (Zaditen tablets), and biological fluid (urine). The direct potentiometric determination of KTF using the proposed sensors gave recoveries % of 98.97 ± 0.53 and 98.62 ± 0.74 with RSD 1.42 and 0.63% for CPE and PVC membrane selective electrodes, respectively. Validation of the method shows suitability of the proposed sensors for use in quality control assessment of KTF. The obtained results were in a good agreement with those obtained using the reported spectrophotometric method.
机译:这项研究比较了未改性的碳糊(CPE;该糊没有离子对)和聚氯乙烯(PVC)膜选择性电极,后者用于电位测定富马酸酮替芬(KTF),其中四苯硼酸钠(NaTPB)被用作滴定剂。根据IUPAC的建议评估了这些传感器的性能特征,揭示了在10 −7 至10 −2 浓度范围内KTF的快速,稳定和线性响应mol L -1 。电极在30°C下的CPE和PVC膜电极的Nernstian斜率分别为52.51±0.20和51.51±0.25 mV decade -1 。在CPE和PVC膜电极的pH范围分别为3.0-6.0和2.0-7.0时,电势几乎稳定。选择性不同无机阳离子,糖和氨基酸反映了所制备电极的高选择性。电极在不同温度下的反应也经过研究,CPE的使用寿命长达12和5周分别发现了PVC膜电极和PVC膜电极。这些是用于电位滴定法测定富马酸酮替芬纯的滴定,校准和标准添加方法样品,其药物制剂(Zaditen片)和生物液(尿液)。直接电位测定使用建议的传感器对KTF的回收率分别为CPE和PVC膜选择电极,回收率分别为98.97±0.53和98.62±0.74,RSD为1.42和0.63%。该方法的验证表明所提出的传感器适用于KTF的质量控制评估。获得的结果与使用报道的分光光度法获得的结果吻合良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号