摘要

BackgroundNon-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)2/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures.
机译:背景技术可以准确估计心输出量的非侵入性措施可能有助于识别容量反应性患者。本研究旨在比较两种非侵入性测量(校正的颈动脉血流时间和颈动脉血流)及其与心输出量的侵入性参考测量的相关性。纳入2016年2月至2016年4月间在马萨诸塞州总医院心脏导管实验室接受右心导管检查的同意成年患者(n = 51)。在没有严重三尖瓣关闭不全的情况下,通过热稀释法获得心律输出,同时获得心输出量,否则通过Fick氧气法获得。校正后的颈动脉血流时间计算为心脏收缩时间/√周期时间。颈动脉血流量计算为π×(颈动脉直径) 2 / 4×速度时间积分×心率。使用单个颈动脉波形和两个颈动脉波形的平均值获得测量值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号