首页> 中文期刊> 《天津大学学报:英文版》 >20 MHz Switched-Current Sample-and-Hold Circuit with Low Charge Injection

20 MHz Switched-Current Sample-and-Hold Circuit with Low Charge Injection

         

摘要

A switched-current sample-and-hold circuit with low charge injection was proposed. To obtain low noise and charge injection, the zero-voltage switching was used to remove the signal-dependent charge injection, and the signal-independent charge injection was reduced by removing the feed-through voltage from the input port of the memory transistor directly. This current sample-and-hold circuit was implemented using CMOS 180 nm 1.8 V technology. For a 0.8 MHz sinusoidal signal input, the simulated signal-to-noise and distortion ratio and total harmonic distortion were improved from 53.74 dB and -51.24 dB to 56.53 dB and -54.36 dB at the sampling rate of 20 MHz respectively, with accuracy of 9.01 bit and power consumption of 0.44 mW.