首页> 中文期刊> 《印染助剂》 >阴离子表面活性剂离子选择电极分析十二烷基苯磺酸钠/烷基糖苷混合体系

阴离子表面活性剂离子选择电极分析十二烷基苯磺酸钠/烷基糖苷混合体系

         

摘要

利用自制阴离子表面活性剂离子选择电极,用电位滴定法测定了非离子表面活性剂烷基糖苷(APG)与阴离子表面活性剂十二烷基苯磺酸钠(SDBS)混合溶液中SDBS的浓度.结果表明:当混合溶液中n(APG)∶n(SDBS)小于2∶1时,可用此方法直接测定混合体系中的SDBS浓度,与滴定单一的SDBS溶液结果对照,滴定终点消耗海明标准溶液体积的相对误差在1.0%以内.%The concentration of sodium dodecyl benzene sulfonate (SDBS) in the mixed nonionic surfactant alkyl polyglucoside (APG) and anionic surfactant SDBS solution was determined by potentiometic titration with self-made anionic surfactant ion-selective electrode. The results indicated that when n(APG): n(SDBS) was less than 2:1, the concentration of SDBS in the mixed solution could be directly determined by potentiometic titration. The relative error of titration endpoint consuming Hamming standard solution volume was less than 1.0% compared with the result obtained from a single SDBS solution.