摘要

IEEE已经成立了100 Gbit/s以太无源光网络(100 Gbit/s-EPON)任务组研究下一代100 Gbit/s PON标准,双二进制检测技术是基带技术选择之一.对基于10 Gbit/s-PON接收机的25 Gbit/s双二进制(DB)检测传输性能进行了实验验证.由于10 Gbit/s-PON接收机带宽受限明显,10 Gbit/s-PON接收机输出的25 Gbit/s双二进制信号会受到码间干扰(ISI)影响.实验结果表明,基于直接判决法的系统接收灵敏度只有-22 dBm,采用最简最大似然序列估计(MLSE)软判决法的系统接收灵敏度能提升到-24.5 dBm.%IEEE has formed the 100 Gbit/s-EPON Task Force to develop next 100 Gbit/s-PON standards,and the duo-binary(DB) detection is one of the baseband technology options.25 Gbit/s DB detection transmission performance with 10 Gbit/s-PON receiver was been experimentally demonstrated.Because the bandwidth of 10 Gbit/s-PON receiver is obviously limited,the 25 Gbit/s DB output signal from 10 Gbit/s-PON receiver will be affected by the inter-symbol interference(ISI).The experiment results show that the system receiving sensitivity based on direct decision method is only-22 dBm.However,the system receiving sensitivity can be up to-24.5 dBm by using the most simplified maximum likelihood sequence estimation(MLSE) soft decision method.