首页>
中文期刊>
《等离子体科学和技术:英文版》
>Accurate quantitative CF-LIBS analysis of both major and minor elements in alloys via iterative correction of plasma temperature and spectral intensity
Accurate quantitative CF-LIBS analysis of both major and minor elements in alloys via iterative correction of plasma temperature and spectral intensity
The chemical composition of alloys directly determines their mechanical behaviors and application fields. Accurate and rapid analysis of both major and minor elements in alloys plays a key role in metallurgy quality control and material classification processes. A quantitative calibration-free laser-induced breakdown spectroscopy(CF-LIBS) analysis method, which carries out combined correction of plasma temperature and spectral intensity by using a secondorder iterative algorithm and two boundary standard samples, is proposed to realize accurate composition measurements. Experimental results show that, compared to conventional CF-LIBS analysis, the relative errors for major elements Cu and Zn and minor element Pb in the copperlead alloys has been reduced from 12%, 26% and 32% to 1.8%, 2.7% and 13.4%, respectively.The measurement accuracy for all elements has been improved substantially.
展开▼