首页> 外文期刊>畜牧与生物技术杂志:英文版 >Prediction of meat quality traits in the abattoir using portable near-infrared spectrometers:heritability of predicted traits and genetic correlations with laboratory-measured traits
【24h】

Prediction of meat quality traits in the abattoir using portable near-infrared spectrometers:heritability of predicted traits and genetic correlations with laboratory-measured traits

机译:Prediction of meat quality traits in the abattoir using portable near-infrared spectrometers:heritability of predicted traits and genetic correlations with laboratory-measured traits

获取原文
获取原文并翻译 | 示例
       

摘要

Background:The possibility of assessing meat quality traits over the meat chain is strongly limited,especially in the context of selective breeding which requires a large number of phenotypes.The main objective of this study was to investigate the suitability of portable infrared spectrometers for phenotyping beef cattle aiming to genetically improving the quality of their meat.Meat quality traits(pH,color,water holding capacity,tenderness)were appraised on rib eye muscle samples of 1,327 Piemontese young bulls using traditional(i.e.,reference/gold standard)laboratory analyses;the same traits were also predicted from spectra acquired at the abattoir on the intact muscle surface of the same animals 1 d after slaughtering.Genetic parameters were estimated for both laboratory measures of meat quality traits and their spectra-based predictions.Results:The prediction performances of the calibration equations,assessed through external validation,were satisfactory for color traits(R^(2) from 0.52 to 0.80),low for pH and purge losses(R^(2) around 0.30),and very poor for cooking losses and tenderness(R^(2) below 0.20).Except for lightness and purge losses,the heritability estimates of most of the predicted traits were lower than those of the measured traits while the genetic correlations between measured and predicted traits were high(average value 0.81).Conclusions:Results showed that NIRS predictions of color traits,pH,and purge losses could be used as indicator traits for the indirect genetic selection of the reference quality phenotypes.Results for cooking losses were less effective,while the NIR predictions of tenderness were affected by a relatively high uncertainty of estimate.Overall,genetic selection of some meat quality traits,whose direct phenotyping is difficult,can benefit of the application of infrared spectrometers technology.

著录项

  • 来源
    《畜牧与生物技术杂志:英文版》 |2021年第003期|P.1214-1225|共12页
  • 作者单位

    Associazione Nazionale Allevatori Bovini di Razza Piemontese strada provinciale Trinita’32/A 12061 Carrù CN ItalyDepartment of Agronomy Food Natural Resources Animals and Environment(DAFNAE) University of Padova(Padua) viale dell’Università16 35020 Legnaro PD Italy;

    Associazione Nazionale Allevatori Bovini di Razza Piemontese strada provinciale Trinita’32/A 12061 Carrù CN Italy;

    Department of Agricultural Forest and Food Sciences University of Torino Via L.Da Vinci 44 10095 Grugliasco TO Italy;

    Department of Agricultural Forest and Food Sciences University of Torino Via L.Da Vinci 44 10095 Grugliasco TO Italy;

    Department of Agronomy Food Natural Resources Animals and Environment(DAFNAE) University of Padova(Padua) viale dell’Università16 35020 Legnaro PD Italy;

    Department of Agronomy Food Natural Resources Animals and Environment(DAFNAE) University of Padova(Padua) viale dell’Università16 35020 Legnaro PD Italy;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 禾谷类作物;
  • 关键词

    Genetic parameters; Meat quality; Near-infrared spectroscopy; Piemontese;