首页> 中文期刊> 《广州化工》 >火力发电厂脱硝氨区防雷设计

火力发电厂脱硝氨区防雷设计

         

摘要

Denitration ammonia area was a chemical workshop of fossil fired power plant, which was one of the new facilities. The electric power industry design, operation and management engineer were biased for understanding of ammonia area lightning protection facilities. The lightning protection design code of denitration ammonia area was analyzed in detail, based on the petrochemical and building lightning protection specification. Combined with some completed projects on ammonia in lightning protection design, the guiding suggestion, and reference for design and operation management engineer were put forward.%脱硝氨区是火力发电厂的一个化工车间,是火电厂的新设施之一,电力行业设计、运行管理技术人员对氨区防雷设施认识上有偏差。就氨区防雷设计依据的石化和建筑防雷规范详细论述,并结合多个实施项目经验对氨区防雷设计提出指导性建议,供设计和运行管理工程技术人员借鉴参考。