Ultrasound Biomicroscopic Dark Room Provocative Test

         

摘要

<正> Purpose : To compare the clinical application value of Ultrasound biomicrsocpic dark room provocative test with the traditional dark room test in screening primary angle closure glaucoma (PACG).Methods: 22 eyes with PACG in prodromal stage and 30 eyes with deep anterior chamber and wide angle of 15 normal persons were observed in this trail. All 52 eyes were performed traditional dark room provocative test and ultrasound biomicorosopic darkroom test respectively. With different positive diagnostic criteria, the sensitivity of the two methods were compared using chi-squared analysis.Results : After staying in the dark room for 2 hours, In case group, IOP in 10 of 22 eyes rose more than 1. 07kPa(1kPa = 7.5mmHg), in 12 eyes less than 1.07kPa or had no changes; appositional angle closure were found by Goldmann gonioscopy in 8 eyes : 3 eyes in two quadrants, 5 eyes in more than two quadrants; the appositional angle closure was found by UBM in 15 eyes; 3 eyes in one quadrants, 5 eyes in two quadrants, 7 eyes