This article gives an overview of using the ground source heat pump (GSHP) and air-to-water heat pump (A&WHP) in cold climate areas for heating and for domestic hot water production of buildings. Computer simulation and analysis were carried out for a typical detached house, with 200 m2 of living area, the heat demand of 9 kW and the average heat demand for DHW production of 1 kW. In heating period the average Coefficient of Performance (COP) of the A&WHP is considerably lower than COP of the GSHP.