首页> 中文期刊> 《职业病与环境医学(英文)》 >Risk Factors Associated with Non-Compliance with Respiratory Protection Programs among Firefighters

Risk Factors Associated with Non-Compliance with Respiratory Protection Programs among Firefighters

         

摘要

Non-compliance with respiratory protection programs among firefighters may put them at increased risk of injury and illness from occupational exposures during fire extinguishing activities. This research aims to characterize respiratory protection practices among Florida firefighters. This information will allow better understanding of factors that are associated with non-compliance with respiratory protection guidelines. A survey questionnaire was used to characterize Florida fire departments in this cross-sectional study. Four hundred and seventy-seven surveys were administered to Florida firefighters both in person and electronically to collect information regarding firefighter knowledge and participation in their respective respiratory protection programs during the past twelve months. Survey questions were developed from the model set by the National Fire Protection Association (NFPA) which provides standards and regulations regarding firefighter protections. Summary statistics regarding firefighter department size, coverage area, and firefighter employment type were produced. Multinomial logistic regression analysis was performed to evaluate factors that impact respiratory protection programs. The 477 respondents were 91% male with a mean age of 39 years old (range 21 - 65 years). The majority of respondents, 76%, were non-smokers, 21% former smokers, and 3% current smokers. In regard to ethnicity, respondents were 77% Caucasian, 13% Hispanic, 3% African American, and 4% other. Most respondents were career firefighters, 97%, with less than ten years of experience, 44%, working in a fire department with at least 21 firefighters, 98%. Most respondents, 80%, had a written respiratory program in place. The most cited reason for not having implemented a written respiratory protection program was lack of knowledge related to the program. Multinomial logistic regression analysis of departments with response areas of at least 250,000 square miles produced a statistically significant 0.444 (0.219 - 0.901 CI) odds ratio for having a written respiratory program as compared to those with a less than 10,000 square miles response area. Additional resources need to be given to Florida fire departments to ensure that all firefighters receive adequate respiratory protection in accordance with NFPA guidelines. There is an association between fire departments with large response areas and non-compliance with respiratory protection guidelines in regard to: having a written respiratory program, the frequency of respiratory fit testing, and the frequency of medical fitness testing. This suggests that rural fire departments need additional resources to ensure firefighters are adequately protected. Additional research should focus on why these differences exist in the rural fire departments. Respondents stating a lack of knowledge or no requirement for a written respiratory program suggest that future efforts should focus on respiratory protection education and training.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号