首页> 中文期刊> 《结构耐久性与健康监测(英文)》 >Seismic Vulnerability Analysis of Single-Story Reinforced Concrete Industrial Buildings with Seismic Fortification

Seismic Vulnerability Analysis of Single-Story Reinforced Concrete Industrial Buildings with Seismic Fortification

         

摘要

As there is a lack of earthquake damage data for factory buildings with seismic fortifications in China,seismic vulnerability analysis was performed by numerical simulation in this paper.The earthquake-structure analysis model was developed with considering the influence of uncertainties of the ground motion and structural model parameters.The small-size sampling was conducted based on the Latin hypercube sampling and orthogonal design methods.Using nonlinear analysis,the seismic vulnerability curves and damage probability matrix with various seismic fortification intensities(SFI)were obtained.The seismic capacity of the factory building was then evaluated.The results showed that,with different designs at different SFIs,the factory building could consistently achieve the three seismic fortification objectives.For the studied factory buildings with the SFI of 6,they satisfied the seismic fortification requirements of“no damage in moderate earthquakes,mendable in strong earthquakes”;for those buildings with SFIs of 7 and 8,the requirement of“no collapsing in super strong earthquakes”was generally met;while for those with SFIs of 9,the requirement of“mendable in moderate earthquakes”was almost satisfied.The results showed factory buildings designed with low SFIs are better at achieving the seismic fortification objectives than those designed with high SFIs.