Background Safe placement of the screws is a critical aspect of trans-pedicle internal fixation,and little information on in vivo morphology of the cervical vertebrae pedicle measured with imaging methods is available.The aim of this study was to measure the dimensions of cervical vertebrae C3 to C7 and provide screw length,screw diameter and tilt angle for clinical cervical vertebra trans-pedicle internal fixation.Methods Thirty Chinese men and women underwent high-speed spiral computed tomography measurements to obtain data for C3 to C7,and the morphology of the cervical vertebra pedicles was reconstructed.Results Reconstructed computer tomography image data revealed that:(1) pedicle sponge width increased incrementally from C3 to C7,(2) pedicle depth was similar for C3 to C7,(3) pedicle angle decreased incrementally from 47.20° to 33.76° for C3 to C7,and (4) pedicle point to midline distance was similar for C3 to C7.There were no statistical differences in morphological data between the right and the left side.Men had statistically larger values than women for all morphological parameters.Conclusions Reconstructed computed tomography images can provide useful data for clinical cervical vertebra trans-pedicle internal fixation.The individual measurement of cervical vertebra pedicles is recommended for safe placement of trans-vertebra pedicle screws.
机译:背景技术螺钉的安全放置是跨椎弓根内固定的一个关键方面,有关利用成像方法测量的颈椎椎弓根的体内形态的信息很少。本研究的目的是测量颈椎C3的尺寸。方法为30例中国男性和女性进行高速螺旋CT扫描,以获取C3至C7的数据以及宫颈的形态学信息,为临床颈椎经椎弓根内固定提供螺钉长度,螺钉直径和倾斜角度。结果重建的计算机断层扫描图像数据显示:(1)椎弓根海绵宽度从C3到C7逐渐增加,(2)椎弓根深度从C3到C7相似,(3)椎弓根角度从47.20°逐渐减小到C3至C7为33.76°,(4)椎弓根点至中线距离与C3至C7相似。形态学数据之间无统计学差异男性和男性在所有形态学参数上的统计学值均高于女性。结论重建的计算机断层扫描图像可为临床颈椎椎弓根内固定术提供有用的数据。为了安全起见,建议单独测量颈椎椎弓根放置跨椎椎弓根螺钉。

著录项

  • 来源
    《中华医学杂志(英文版)》 |2012年第14期|2521-2524|共4页
  • 作者单位

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

    Trauma and Orthopaedics Department, Peking University People's Hospital, Beijing 100044, China;

  • 收录信息 中国科学引文数据库(CSCD);中国科技论文与引文数据库(CSTPCD);
  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号