首页> 外文学位 >Phenyl Functionalized Sol-gel Silica Sorbent for Capillary Microextraction and Chromia-Based Sol-gel Ucon Stationary Phase for Capillary Gas Chromatography.
【24h】

Phenyl Functionalized Sol-gel Silica Sorbent for Capillary Microextraction and Chromia-Based Sol-gel Ucon Stationary Phase for Capillary Gas Chromatography.

机译:用于毛细管微萃取的苯基官能化溶胶-凝胶硅胶吸附剂和用于毛细管气相色谱的基于铬的溶胶-凝胶Ucon固定相。

获取原文
获取原文并翻译 | 示例

摘要

The first chapter of this thesis presents an introduction to sol-gel methodology whose usefulness as a synthetic route will be demonstrated with two applications in chromatography. The first application involves the fabrication of a capillary micro-extraction (CME) device by coating a phenyl functionalized extracting phase on the inner surface of a fused silica capillary for analyte pre-concentration. The device was coupled on-line to a RP-HPLC system and practicality was demonstrated using allergens as target analytes. The allergens chosen as model analytes are typically found in fragrance products and food. Most of the 26 fragrance allergens that are monitored by various government authorities have a phenyl organic moiety (a strong chromophore), thus making them appropriate probes for exploring the extraction efficiency of the coating using a UV detector. The CME device showed ppt level limit of detection which makes it suitable for trace analyses of allergens and similar compounds in a variety of matrices.;The second application explores the feasibility of using sol-gel derived chromia-based stationary phase in gas chromatographic columns. The organic moiety of the stationary phase was derived from Ucon 75-H-90,000 while the inorganic backbone was prepared using chromium(III) dichloride hydroxide - methacrylic acid - aqua complex, 40% in isopropanol/acetone . Usefulness of prepared chromia-based GC stationary phase was examined for petrochemical application. Promising results were obtained using aliphatic-aromatics, polyaromatic hydrocarbons, BTEX test mixture, cycloalkanes, branched alkanes and akylbenzenes. The column was able to perform without degradation despite being rinsed multiples times sequentially with the following solvents: dichloromethane, methanol, water and finally methanol again. Maximum theoretical plate number calculated is around 2,400 plates/m. The plate number clearly needs improvement but is a promising result for the newly explored chromia-based stationary phase. The maximum programmable temperature is 250°C which is comparable with similar commercially available polar stationary phases.
机译:本论文的第一章介绍了溶胶-凝胶法,其在两种色谱中的应用将证明其作为合成路线的有效性。第一项应用涉及通过在熔融石英毛细管的内表面涂覆苯基官能化的萃取相以进行分析物预浓缩来制造毛细管微萃取(CME)装置。将该设备在线连接到RP-HPLC系统,并使用过敏原作为目标分析物证明了实用性。被选作模型分析物的过敏原通常存在于香料产品和食品中。由各种政府机构监控的26种芳香剂过敏原中大多数具有苯基有机部分(强发色团),因此使其成为使用UV检测器探索涂层提取效率的合适探针。 CME设备显示出ppt检测限,使其适用于多种基质中的过敏原和类似化合物的痕量分析。;第二个应用探索了在气相色谱柱中使用溶胶-凝胶衍生的基于色度的固定相的可行性。固定相的有机部分衍生自Ucon 75-H-90,000,而无机骨架则使用40%异丙醇/丙酮中的氢氧化二氯化铬(III)-甲基丙烯酸-水配合物制备。检查了制备的基于氧化铬的气相色谱固定相在石油化学应用中的有用性。使用脂族-芳族化合物,聚芳族烃,BTEX测试混合物,环烷烃,支链烷烃和烷基苯可获得令人鼓舞的结果。尽管用以下溶剂依次冲洗了多次,但该色谱柱仍能够运行而不会降解:二氯甲烷,甲醇,水,最后再用甲醇冲洗。计算的最大理论塔板数约为2,400板/米。板数显然需要改进,但对于新探索的基于色度的固定相来说是一个有希望的结果。最高可编程温度为250°C,可与类似的市售极性固定相媲美。

著录项

  • 作者

    McLean, Michael M.;

  • 作者单位

    University of South Florida.;

  • 授予单位 University of South Florida.;
  • 学科 Chemistry Analytical.;Engineering Materials Science.
  • 学位 M.S.
  • 年度 2014
  • 页码 129 p.
  • 总页数 129
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号