首页> 外文学位 >A DSP controlled resonant active filter for current harmonic mitigation in three-phase power systems.
【24h】

A DSP controlled resonant active filter for current harmonic mitigation in three-phase power systems.

机译:DSP控制的谐振有源滤波器,用于减轻三相电力系统中的电流谐波。

获取原文
获取原文并翻译 | 示例

摘要

Power quality has become an important concern to both electric utilities and end users due to the increased use of non-linear loads in modern power systems over the past decade. Nonlinear loads inject harmonics into the power system and thus may lead to poor power quality and lower power factor. Current and voltage harmonics can adversely affect the operation of sensitive devices.; A common remedial solution to reduce the effects of harmonic distortion in a power system is filtering. Passive and active filters are two common types of harmonic filters. An active filter, in general, is a controllable current source that injects current at the same magnitude and opposite phase to that of the harmonic current. For this thesis work, a DSP-controlled active filter to cancel lower order (5th, 7th, 11th, and 13th) harmonics in a three-phase, three-wire power system is designed. The proposed active filter employs a series LC tank tuned to a high frequency, along with a pulse-width modulated (PWM) converter topology. The PWM control of the active filter is implemented in a TMS320F240 DSP. The DSP implementation enhances the performance of the filter in real-time and enables the filter to compensate for varying loads. Additionally, the use of DSP-control reduces the number of components and therefore reduces the cost and improves the reliability of the overall system. The uniqueness of the filter is in its ability to control each harmonic separately. A laboratory prototype of the proposed active filter has been built and tested to verify the performance of the active filter.
机译:由于过去十年来现代电力系统中非线性负载的使用不断增加,电能质量已成为电力公司和最终用户的重要关注点。非线性负载将谐波注入电力系统,因此可能导致不良的电能质量和较低的功率因数。电流和电压谐波会严重影响敏感设备的运行。减少电力系统中谐波失真影响的常用补救方法是滤波。无源和有源滤波器是谐波滤波器的两种常见类型。通常,有源滤波器是一种可控电流源,它以与谐波电流相同的幅度和相反的相位注入电流。对于本文的工作,使用 DSP 控制的有源滤波器来消除低阶(第5 ,第7 ,第11 和13 次谐波。所提出的有源滤波器采用了调谐到高频的串联LC谐振电路以及脉宽调制( PWM )转换器拓扑。有源滤波器的 PWM 控制在TMS320F240 DSP 中实现。 DSP 实现可实时增强滤波器的性能,并使滤波器能够补偿变化的负载。另外,使用 DSP -control减少了组件数量,因此降低了成本并提高了整个系统的可靠性。滤波器的独特之处在于其分别控制每个谐波的能力。已构建并测试了所提出的有源滤波器的实验室原型,以验证有源滤波器的性能。

著录项

  • 作者

    Unsal, Abdurrahman.;

  • 作者单位

    Oregon State University.;

  • 授予单位 Oregon State University.;
  • 学科 Engineering Electronics and Electrical.
  • 学位 Ph.D.
  • 年度 2001
  • 页码 160 p.
  • 总页数 160
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 无线电电子学、电信技术;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号