首页> 外文学位 >The use of a beta'-alumina electrolyte as sodium vapor sensor for the determination of sodium hydroxide in a glass tank.
【24h】

The use of a beta'-alumina electrolyte as sodium vapor sensor for the determination of sodium hydroxide in a glass tank.

机译:使用β“-氧化铝电解质作为钠蒸气传感器来测定玻璃罐中的氢氧化钠。

获取原文
获取原文并翻译 | 示例

摘要

A β-alumina electrolyte was used as a Na vapor sensor at 1500°C for application in the determination of NaOH in a glass tank. The difference in NaOH potential between both sides of the electrolyte gives the potential difference. Several experiments were carried out in a glass tank simulator at 1500°C while batch was added to the furnace. Also some experiments were done under controlled conditions (520–625 ppm NaOH and 1500°C) in a small tube furnace. Some stability experiments were done at 1400 and 1500°C and 250 and 1040 ppm of NaOH for both temperatures at several times. The sensor responded to sudden changes in sodium hydroxide (NaOH) every time that batch was added to the glass furnace. Decay in the mV signal was observed in those experiments. Experiments under controlled conditions also showed decay in the signal for NaOH concentrations in the range of 520–625 ppm of NaOH. XRD analysis, and SEM and CL micrographs from samples used in the stability experiments, as well as samples from the glass furnace and tube furnace, showed changes in the microstructure. The β phase transformed to β and α-alumina during the exposure to the furnace at 1500°C for several hours. The change in phase changes the Na2O activity in the electrolyte and therefore was one factor contributing to the decrease in the signal. Sensors can be used to show relative changes in NaOH. The use of an electrolyte containing a mixture of α + β is proposed and justified.
机译:将β''-氧化铝电解质作为Na蒸气传感器在1500℃下用于玻璃罐中NaOH的测定。电解质两侧之间的NaOH电位差给出了电位差。在将批料添加到炉中的同时,在玻璃罐模拟器中于1500°C进行了几次实验。另外,在小型管式炉中在受控条件(520–625 ppm NaOH和1500°C)下进行了一些实验。在这两个温度下,分别在1400和1500°C以及250和1040 ppm的NaOH下进行了几次稳定性实验。每次将批次添加到玻璃炉中时,传感器都会响应氢氧化钠(NaOH)的突然变化。在那些实验中观察到了mV信号的衰减。在受控条件下进行的实验还显示,NaOH浓度在520-625 ppm范围内时信号衰减。 XRD分析,稳定性实验中使用的样品以及玻璃炉和管式炉的SEM和CL显微照片均显示出微观结构的变化。在暴露于1500°C的炉中数小时后,β''相转变为β和α-氧化铝。相变改变了电解质中的Na 2 O活性,因此是导致信号降低的因素之一。传感器可用于显示NaOH的相对变化。提出并证明了使用包含α+β的混合物的电解质。

著录项

  • 作者单位

    University of Missouri - Rolla.;

  • 授予单位 University of Missouri - Rolla.;
  • 学科 Engineering Materials Science.
  • 学位 Ph.D.
  • 年度 2003
  • 页码 225 p.
  • 总页数 225
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工程材料学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号