首页> 外文学位 >Accelerated corrosion testing, evaluation and durability design of bonded post-tensioned concrete tendons.
【24h】

Accelerated corrosion testing, evaluation and durability design of bonded post-tensioned concrete tendons.

机译:加速后粘结混凝土预应力筋的腐蚀测试,评估和耐久性设计。

获取原文
获取原文并翻译 | 示例

摘要

In the last few years, the effectiveness of cement grout in galvanized or polyethylene ducts, the most widely used corrosion protection system for multistrand bonded post-tensioned concrete tendons, has been under debate, due to significant tendon corrosion damage, several reported failures of individual tendons as well as a few collapses of non-typical structures. While experience in the USA has been generally good, some foreign experience has been less than satisfactory.; This dissertation is part of a comprehensive research program started in 1993, which has the objectives to examine the use of post-tensioning in bridge substructures, identify durability concerns and existing technology, develop and carry out an experimental testing program, and conclude with durability design guidelines.; Three experimental programs were developed: A long term macrocell corrosion test series, to investigate corrosion protection for internal tendons in precast segmental construction; a long term beam corrosion test series, to examine the effects of post-tensioning on corrosion protection as affected by crack width; and, a long term column corrosion test series, to examine corrosion protection in vertical elements.; Preliminary design guidelines were developed previously in the overall study by the initial researchers, after an extensive literature review.; This dissertation scope includes continuation of exposure testing of the macrocell, beam and column specimens, performing comprehensive autopsies of selected specimens and updating the durability design guidelines based on the exposure testing and autopsy results.; After autopsies were performed, overall findings indicate negative durability effects due to the use of mixed reinforcement, small concrete covers, galvanized steel ducts, and industry standard or heat-shrink galvanized duct splices. The width of cracks was shown to have a direct negative effect on specimen performance. Grout voids were found to be detrimental to the durability of both galvanized ducts and strand. Relying on epoxy and galvanized bar coatings was also found inappropriate because of local attack. On the other hand, very positive effects were found with the use of high performance concrete, high post-tensioning levels, plastic ducts, and sound epoxy filling at the joints.
机译:在过去的几年中,由于显着的钢筋束腐蚀损坏,个别已报告的几项失败,镀锌或聚乙烯管道中水泥浆在有效性方面的应用一直受到争议,镀锌或聚乙烯管道是最广泛使用的多股粘结后张拉混凝土钢筋束的腐蚀防护系统。肌腱以及一些非典型结构的坍塌。虽然在美国的经验总体上不错,但一些国外经验却不令人满意。本论文是一项始于1993年的综合研究计划的一部分,该计划的目的是检查桥梁子结构中后张法的使用,确定耐久性问题和现有技术,制定和执行实验测试程序并得出耐久性设计结论准则。开发了三个实验程序:长期宏单元腐蚀测试系列,以研究预制分段施工中内部钢筋的腐蚀防护;长期的梁腐蚀试验系列,以检验受裂纹宽度影响的后张对腐蚀防护的影响;长期的柱腐蚀试验系列,以检查垂直元件的腐蚀防护。初步的设计指南是在最初的研究人员经过大量文献综述后,在整体研究中制定的。论文的范围包括继续对大单元,梁和柱样品进行暴露测试,对选定的样品进行全面的尸检,并根据暴露测试和尸检结果更新耐久性设计指南。进行尸检后,总体结果表明,由于使用了混合钢筋,较小的混凝土覆盖层,镀锌钢管,工业标准或热缩镀锌导管接头,因此对耐久性产生了负面影响。结果表明,裂纹的宽度对样品的性能有直接的负面影响。发现灌浆空隙不利于镀锌管和钢绞线的耐用性。由于局部侵蚀,还发现依靠环氧和镀锌的条形涂料是不合适的。另一方面,通过使用高性能混凝土,高后张强度,塑料管道和在接缝处充填良好的环氧树脂,发现了非常积极的效果。

著录项

  • 作者

    Salas Pereira, Ruben Mario.;

  • 作者单位

    The University of Texas at Austin.;

  • 授予单位 The University of Texas at Austin.;
  • 学科 Engineering Civil.; Engineering Materials Science.
  • 学位 Ph.D.
  • 年度 2003
  • 页码 716 p.
  • 总页数 716
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 建筑科学;工程材料学;