摘要

New innovations in seismic load resisting systems have recognized the approach of isolating inelastic deformations to primary, permanently attached components may, in fact, be flawed. The current design approach is to provide systems that withstand relatively large story drifts, while experiencing controlled inelastic deformations to dissipate energy. By isolating inelastic deformations to easily accessible, bolted components that can be relatively inexpensively removed and replaced, a serviceable seismic system can be achieved.;This research investigates the viability of a fully bolted configuration of a buckling restrained brace frame (BRBF). It contains the results of two full-scale BRBF one-bay, one-story frame tests. The frame connections were detailed such that after a major seismic event the brace would absorb most of the inelastic energy. The brace acts as the replaceable "fuse" in the serviceable system, being the only primary structural component replaced from one test to the next. The Appendix T of ANSI/AISC 341-05 (AISC 341, 2005) translation/drift test regime was used. The first BRB (WC 250) and connections performed well and the system illustrated robust and stable hysteric behavior. The frame was re-plumbed and another brace (WC 200) was installed.;This research contains the test description and results for global behavior for the frame and local strains in areas of interest. It was demonstrated that the connection details can accommodate the significant drift requirements. The information from these tests was used to develop recommendations for proportioning and configuring the members and connections.
机译:抗地震载荷系统的新创新已经认识到将非弹性变形隔离到永久固定的主要部件上的方法实际上可能存在缺陷。当前的设计方法是提供能够承受相对较大的楼层漂移,同时经历受控的非弹性变形以耗散能量的系统。通过将非弹性变形隔离到可以相对便宜地拆卸和更换的,易于接近的螺栓连接组件,可以实现可维修的地震系统。本研究研究了屈曲约束支撑框架(BRBF)的完全螺栓连接构型的可行性。它包含两个完整的BRBF单托架,一层框架测试的结果。详细说明了框架连接,以便在发生重大地震事件后,支架将吸收大部分非弹性能。支架充当可维修系统中的可替换“保险丝”,是从一个测试到下一个测试的唯一主要结构部件。使用了ANSI / AISC 341-05(AISC 341,2005)转换/漂移测试方案的附录T。第一个BRB(WC 250)和连接的性能良好,系统说明了强大而稳定的磁滞行为。重新安装框架,并安装另一个支架(WC 200)。该研究包含框架的整体性能和目标区域局部应变的测试说明和结果。事实证明,连接细节可以满足明显的漂移要求。这些测试中的信息用于制定有关按比例分配和配置成员和连接的建议。

著录项

  • 作者

    MacMahon, Addison M.;

  • 作者单位

    University of Wyoming.;

  • 授予单位 University of Wyoming.;
  • 学科 Engineering Civil.
  • 学位 M.S.
  • 年度 2011
  • 页码 116 p.
  • 总页数 116
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号