A novel method was investigated for the quantification of 210 Po in water as an alternative to the standard method of spontaneous plating onto Ag disks followed by quantification with an alpha spectrometer. The novel method concentrated a 0.5L sample by MnO2 co-precipitation followed by dissolution of the precipitate into a solution. Polonium-210 was separated from the solution and quantified in a column containing a 50:50 by volume mixture of Pb resin (Eichrom Technologies, Inc.) mixed with granulated CaF2:Eu scintillator. The column containing 210Po is quantified on a liquid scintillation counter without the introduction of liquid cocktail. The minimum detectable concentration (MDC) is 53 mBq/L for the novel method compared to 2 mBq/L for the standard method. This MDC of the novel method meets the WHO limit of 100 mBq/L, but is significantly higher than the standard method. Polonium-210 concentrations were determined for five groundwaters from locations in upstate region of South Carolina and Nevada. The 210Po concentration as determined for the novel method ranged from Po concentration as determined for the novel method ranged from MDC to 3703.0 mBq/L. Correlation between the concentrations found by the standard and novel methods was not good. In every case where the concentration was above the MDC, the concentration determined by the novel method trended higher, ranging from 37.2% to 90.3 %. In most cases, the higher concentration was attributed to uranium in the groundwater. Due to high variability in the background for the novel method columns, there is significant uncertainty in the concentrations determined by the novel method.
机译:研究了一种用于定量测定水中210 Po含量的新方法,以替代自发镀在Ag盘上的标准方法,然后使用α光谱仪进行定量。该新方法通过MnO2共沉淀来浓缩0.5L样品,然后将沉淀物溶解到溶液中。从溶液中分离出210 210,并在一个含有50:50体积比的Pb树脂(Eichrom Technologies,Inc.)与粒状CaF2:Eu闪烁体混合的混合物中进行定量。在不引入液体混合物的情况下,在液体闪烁计数器上对含有210Po的色谱柱进行定量。新方法的最低可检测浓度(MDC)为53 mBq / L,而标准方法为2 mBq / L。该新方法的MDC符合WHO的100 mBq / L限制,但明显高于标准方法。确定了南卡罗来纳州和内华达州北部地区五种地下水的-210浓度。对于该新方法确定的210Po浓度范围从对于该新方法确定的Po浓度范围在

著录项

  • 作者

    Matheny, Tara Elizabeth.;

  • 作者单位

    Clemson University.;

  • 授予单位 Clemson University.;
  • 学科 Environmental Health.;Geochemistry.
  • 学位 M.S.
  • 年度 2011
  • 页码 111 p.
  • 总页数 111
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号