The failure of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a need to develop realistic methods to quantify the risk of fire to NPP safety. Recent electrical cable testing has been conducted to provide empirical data on the failure modes and likelihood of fire-induced damage. This thesis evaluated numerous aspects of the data. Circuit characteristics affecting fire-induced electrical cable failure modes have been evaluated. In addition, thermal failure temperatures corresponding to cable functional failures have been evaluated to develop realistic single point thermal failure thresholds and probability distributions for specific cable insulation types. Finally, the data was used to evaluate the prediction capabilities of a one-dimension conductive heat transfer model used to predict cable failure.
机译:暴露于严重热火条件下的电缆故障是运行商业核电站(NPP)的安全问题。核监管委员会(NRC)促进了对风险了解和基于性能的方法在消防中的使用,这导致需要开发现实的方法来量化对NPP安全造成火灾的风险。最近进行了电缆测试,以提供有关故障模式和火灾引起的损坏可能性的经验数据。本文评估了数据的许多方面。已经评估了影响着火电缆故障模式的电路特性。此外,已经对与电缆功能故障相对应的热故障温度进行了评估,以针对特定电缆绝缘类型开发出实际的单点热故障阈值和概率分布。最后,该数据用于评估用于预测电缆故障的一维导热模型的预测能力。

著录项

  • 作者

    Taylor, Gabriel James.;

  • 作者单位

    University of Maryland, College Park.;

  • 授予单位 University of Maryland, College Park.;
  • 学科 Engineering Industrial.;Engineering Nuclear.
  • 学位 M.S.
  • 年度 2012
  • 页码 157 p.
  • 总页数 157
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号