A Novel Method for Assessing Leg Compartmental Body Composition Using Dual Energy X-ray Absorptiometry.

机译:一种使用双能X射线吸收测定法评估腿室身体成分的新颖方法。

获取原文
获取原文并翻译 | 示例

摘要

Purpose: Manual segmentation using dual energy X-ray absorptiometry (DXA) is a valid method for quantifying contralateral tissue asymmetries of the body, but has not been used to quantify body composition in the ipsilateral upper leg compartments. The purpose of this study was to examine the validity and reliability of DXA to quantify fat and lean tissue composition in the anterior and posterior thigh compartments. Methods: Twenty-one (10 male/11 female) college athletes (X¯age = 20.3+/-1.3 yrs) were assessed for total and regional body composition. Segmentation of the anterior and posterior thigh compartments was accomplished by scanning participants lying on their right and left sides using DXA (iDXA, General Electric Medical Systems, Madison, WI, USA). Each scan was manually segmented and analyzed by three technicians using enCore(TM) software (platform version 16.0, General Electric Medical Systems, Madison, WI, USA). Custom regions of interest (ROIs) were created from bony landmarks on the femur. In Analysis 1, the proximal border of the custom ROI on the frontal and lateral scans was placed at 40% of the length from the lateral epicondyle to the greater trochanter. The distal border was placed at 40% of the length from the lateral epicondyle to the distal end of the lateral malleolus. Lateral and medial borders were placed outside the leg area. To validate the segmentation method, lateral and frontal scan ROI measures of equal leg area for total, fat, and lean masses for each person and each leg were compared. In Analysis 2, proximal and distal ROI borders were placed at 80% of the length from the lateral epicondyle to the greater trochanter. Lateral and medial ROI borders were placed along the centerline of the shaft of the femur and outside of the leg area, respectively, for the anterior ROI compartment and the opposite for the posterior compartment using the custom area drawing tool to quantify compartmental tissue composition. For Analysis 1 we used paired t-tests to assess differences between the measurement methods for each leg (lateral vs. standard position). To assess intra- and inter-rater reliability for Analysis 2, we used intra-class correlation coefficients (ICC) and coefficients of variation (CV) and compared the lateral segmented technique for measures of total, fat, and lean masses. Results: All comparisons of total, fat, and lean masses between the frontal and lateral DXA scans were non-significant (mean differences in right leg: 0.015+/-0.12 kg, 0.041+/-0.19 kg, -0.0734+/-0.22 kg; mean differences in left leg: 0.041+/-0.12 kg, -0.023+/-0.17 kg, 0.017+/-0.23 kg, respectively; p-value range: 0.15 to 0.74). ICCs were high for all composition measures between- and within-raters, ranging from 0.983 to 0.999 and 0.954 to 0.999, respectively, with low variation across measures (all CVs: <5%). Conclusion: This study suggests that DXA measures using lateral subject positioning and custom ROIs to assess upper leg total, fat, and lean masses are valid and reliable compared with total-body frontal subject positioning. This novel method allows for anterior/posterior compartmental examination of the aforementioned measures using custom ROIs. Future studies are needed to determine the performance and clinical usefulness of lateral position measures regarding prevention or rehabilitation of injury.;Key Words: Dual-Energy X-ray Absorptiometry, Body Composition, Validity, Reliability.
机译:目的:使用双能X线骨密度仪(DXA)进行手动分割是量化身体对侧组织不对称性的有效方法,但尚未用于量化同侧大腿隔室中的身体成分。这项研究的目的是检查DXA量化大腿前部和后部隔室中脂肪和瘦肉组织成分的有效性和可靠性。方法:评估二十一名(10名男性/ 11名女性)大学生(X年龄= 20.3 +/- 1.3岁)的总体和局部身体成分。通过使用DXA(iDXA,通用电气医疗系统公司,麦迪逊,威斯康星州,美国)对位于左右两侧的参与者进行扫描,可以完成对大腿前部和后部的分割。每次扫描都由三名技术人员使用enCore™软件(平台版本16.0,美国通用电气医疗系统,麦迪逊,威斯康星州)进行手动分段和分析。自定义感兴趣区域(ROI)是从股骨上的骨标志创建的。在分析1中,在正面和侧面扫描中自定义ROI的近端边界放置在从侧面上epi到大转子的长度的40%处。从外侧上con到外侧踝远端的长度的40%放置了远端边界。外侧和内侧边界放置在腿部区域之外。为了验证分割方法,比较了每个人和每条腿的总腿,脂肪和瘦体重相等的腿部面积的侧面和正面扫描ROI度量。在分析2中,从外上con到大转子的近端和远端ROI边界的长度占长度的80%。使用定制区域绘图工具分别量化股骨外侧和内侧ROI边界沿股骨干轴的中心线和腿部外侧,对于ROI前侧隔室和后部隔室的相对边界,使用量化的区域绘图工具进行量化。对于分析1,我们使用成对的t检验来评估每条腿(横向与标准姿势)的测量方法之间的差异。为了评估分析2的评估者内部和评估者之间的可靠性,我们使用了类别内相关系数(ICC)和变异系数(CV),并比较了横向分段技术对总重量,脂肪和瘦体重的度量。结果:额骨和外侧DXA扫描之间的总重量,脂肪和瘦体重的所有比较均无统计学意义(右腿平均差异:0.015 +/- 0.12 kg,0.041 +/- 0.19 kg,-0.0734 +/- 0.22 kg;左腿的平均差异:分别为0.041 +/- 0.12 kg,-0.023 +/- 0.17 kg,0.017 +/- 0.23 kg; p值范围:0.15至0.74)。评估者之间和评估者内部的所有构成测度的ICC均较高,分别在0.983至0.999和0.954至0.999的范围内,各测度之间的差异较小(所有CV:<5%)。结论:这项研究表明,与全身额部受试者定位相比,使用侧向受试者定位和自定义ROI评估大腿总,脂肪和瘦体重的DXA测量方法是有效且可靠的。这种新颖的方法允许使用自定义ROI对上述测量进行前/后隔室检查。需要进行进一步的研究以确定有关预防或康复损伤的侧位测量的性能和临床实用性。关键词:双能X线吸收法,身体成分,有效性,可靠性。

著录项

  • 作者

    Raymond, Christiana Joy.;

  • 作者单位

    University of Minnesota.;

  • 授予单位 University of Minnesota.;
  • 学科 Kinesiology.;Physical therapy.;Medical imaging.
  • 学位 M.S.
  • 年度 2016
  • 页码 78 p.
  • 总页数 78
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号