摘要

Abstract: ferential absorption method is the best one from the point of view of its potentialities in applications to solving the problems of sensing atmospheric gaseous pollutants. The middle IR spectral range from 2 to 14 $mu@m is most attractive for measurements since well-resolved absorption spectra of almost all the atmospheric gases are observed here. This paper presents some results of monitoring several trace atmospheric constituents, including CO, C$-2$/H$-4$/ and NH$-3$/ using a gas analyzer, based on the use of two CO$-2$/ lasers and a set of frequency converters. The gas analyzer with a discretely frequency-tuned CO$-2$/ laser was taken as the basic device for this study. Use of a ZnGeP$-2$/ monocrystal for frequency doubling enables one to measure CO concentration in addition to concentrations of ethylene, water vapor, ammonia under field conditions. !1
机译:摘要:从吸收潜力的角度来看,电位吸收法是最好的方法,可用于解决大气中气态污染物的检测问题。中等红外光谱范围从2到14μμm不等,因为在这里观察到几乎所有大气的分辨良好的吸收光谱,因此对测量最为有吸引力。本文介绍了基于使用两种CO $ -2 $的气体分析仪监测几种痕量大气成分的一些结果,包括CO,C $ -2 $ / H $ -4 $ /和NH $ -3 $ /。 /激光器和一组变频器。带有离散频率调谐CO $ -2 $ /激光器的气体分析仪被用作本研究的基本设备。使用ZnGeP $ -2 $ /单晶进行倍频,可以在现场条件下测量乙烯,水蒸气和氨气中的CO浓度。 !1