首页> 外文会议>Sixth International Symposium on Brittle Matrix Composites BMC6, Oct 9-11, 2000, Warsaw, Poland >SHRINKAGE PROPERTIES OF STEEL FIBRE REINFORCED HIGH STRENGTH CONCRETE
【24h】

SHRINKAGE PROPERTIES OF STEEL FIBRE REINFORCED HIGH STRENGTH CONCRETE

机译:钢纤维高强混凝土的收缩性能

获取原文
获取原文并翻译 | 示例

摘要

The paper reports on a study of shrinkage and weight loss behaviour of plain and fibre reinforced high strength concrete (HSC) mixes. Four test specimen sizes were used in the study; three being cylinders with diameters of 100, 150 and 200 mm and a height/diameter ratio of two and the fourth being 76 X 76 X 254 mm prisms. All specimens were subjected to standard air drying (RH 65 +- 5%, Temperature = 20 +- 2℃) for 100 days. In general, the results show that HSC has similar variation of shrinkage and weight loss with time to that observed for normal strength concrete and the relationship between shrinkage and weight loss is linear. The test results have been compared with results obtained from five prediction models and it is concluded that further work is necessary to improve the models before application to HSC.
机译:该论文报道了对普通和纤维增强高强度混凝土(HSC)混合物的收缩和失重行为的研究。在研究中使用了四个测试样本尺寸。三个是直径为100、150和200 mm的圆柱,高度/直径比为两个,第四个是76 X 76 X 254 mm棱镜。所有样品均进行标准风干(RH 65±5%,温度= 20±2℃)100天。通常,结果表明,HSC的收缩率和重量损失随时间变化与普通强度混凝土相似,并且收缩率和重量损失之间的关系呈线性关系。将测试结果与从五个预测模型获得的结果进行了比较,得出的结论是,在应用于HSC之前,需要进一步的工作来改进模型。