Reliability of low-cost wireless sensors for civil infrastructure

机译:用于民用基础设施的低成本无线传感器的可靠性

获取原文
获取原文并翻译 | 示例

摘要

The long-term reliability of a prototype, threshold corrosion sensor is demonstrated using data collected during an eighteen-month accelerated corrosion test. The sensors were embedded in reinforced concrete slabs, subjected to alternating wet/dry cycles, and interrogated periodically during the test. The frequency signature of the sensor changes after the steel sensing wire corrodes, providing a convenient and noninvasive technique for determining when a threshold amount of corrosion has occurred. The results indicate that the sensor data are reliable, but that some variability of readings should be expected due to the close tie between the presence of cracks in the concrete and the chloride levels, as the locations of the cracks are not known at the time that the sensors are embedded in the concrete.
机译:通过在18个月的加速腐蚀测试中收集的数据证明了原型阈值腐蚀传感器的长期可靠性。传感器被嵌入钢筋混凝土板中,经历了湿/干交替循环,并在测试过程中定期被询问。传感器的频率信号在钢制感应线腐蚀后发生变化,从而为确定何时发生阈值腐蚀提供了一种方便且无创的技术。结果表明传感器数据是可靠的,但是由于混凝土中裂缝的存在与氯化物含量之间的紧密联系,因此应该预计读数会有一些变化,因为当时裂缝的位置尚不明确。传感器嵌入混凝土中。