For a recent contract the user specified that the primary heat transport pump and the shutdown pump motors be Environmentally Qualified (EQ) for the applications. This meant that the complete motors including the insulation systems would be tested along the requirements set forth in IEEE 323 [1], IEEE 334 [2], and IEEE 344 [3]. The physical sizes of the machines prevented the actual units from being tested, and hence, component testing became necessary. To environmentally qualify a stator insulation system, including a Loss of Coolant Accident (LOCA) toward the end of a 30 year insulation life, requires the manufacture and testing of statorettes. This paper discusses; (1) the types of problems which can be encountered in this type of exercise, (2) the testing and test results for both a 4kV and a 13.2kV insulation system, (3) the results from testing to feilure of the coils after the completion of the environmental qualification tests. Results of surge, hi-pot, polarization index, and partial discharge tests are presented.
机译:对于最近的合同,用户指定主传热泵和停机泵电机必须符合应用环境标准(EQ)。这意味着将按照IEEE 323 [1],IEEE 334 [2]和IEEE 344 [3]中规定的要求对包括绝缘系统在内的整个电动机进行测试。机器的物理尺寸阻止了实际单元的测试,因此必须进行组件测试。为了使定子绝缘系统达到环保要求,包括在30年绝缘寿命即将结束时发生的冷却剂损失事故(LOCA),需要对定子进行制造和测试。本文讨论; (1)在这种类型的练习中可能遇到的问题的类型;(2)4kV和13.2kV绝缘系统的测试和测试结果;(3)从测试到线圈失效的结果完成环境资格测试。给出了电涌,高压电位,极化指数和局部放电测试的结果。