Exact modeling of streamer propagation requires precise knowledge of their geometry. Earlier evaluations of shadowgraph photographs revealed diameters as low as approximately 25 μm, an energetic balance yields even lower values. To ascertain the geometric condititions, in a point-plane configuration with an electrode distance of 120 mm, pre-discharge phenomena in transformer oil were investigated up to 200 kV alternating voltage. The evaluation revealed that the streamers have a mean diameter of only approx. 12 μm which is significantly less than the previously estimated values.
机译:对拖缆传播进行精确建模需要精确了解其几何形状。皮影照片的早期评估显示直径低至约25μm,能量平衡产生的值甚至更低。为了确定几何条件,在电极距离为120 mm的点平面配置中,研究了交流电压高达200 kV时变压器油中的预放电现象。评估显示,拖缆的平均直径仅为大约。 12μm,大大小于先前的估计值。