首页> 外文会议>Physics of Medical Imaging pt.2; Progress in Biomedical Optics and Imaging; vol.8 no.29; Proceedings of SPIE-The International Society for Optical Engineering; vol.6510 pt.2 >Motion artifact reduction in fan-beam and cone-beam computed tomography via the Fan-beam Data Consistency Condition (FDCC)
【24h】

Motion artifact reduction in fan-beam and cone-beam computed tomography via the Fan-beam Data Consistency Condition (FDCC)

机译:通过扇形束数据一致性条件(FDCC)减少扇形束和锥形束计算机断层扫描中的运动伪影

获取原文
获取原文并翻译 | 示例

摘要

Motion contamination in computed tomography projection data causes significant artifacts in the reconstructed images. If during the tomographic acquisition the object is relatively stationary during a portion of the acquisition, and then moves significantly, the projection data after the motion will be inconsistent with the projection data during the period of relative stationarity. The fan-beam data consistency condition (FDCC) provides a means to directly estimate motion contaminated projection data based on all of the projection data acquired. Thus, the FDCC may be used to combat many types of motion contamination in computed tomography. This approach to motion artifact correction is novel as none of the previous methods for artifact correction utilized a direct estimation of motion contaminated data. Additionally, this methodology depends upon only a small amount of a priori information and is not based on a motion model. Another distinguishing feature of this method is that it operates directly in the projection space, and is completely independent of the reconstruction algorithm utilized. An example of clinical relevance of coronary motion artifact reduction is presented using both simulated projection data as well as projection data acquired with a porcine model using a state-of-the-art 64 row volumetric CT scanner. Significant reduction in motion related artifacts is achieved in both the simulation case and the porcine model.
机译:计算机断层扫描投影数据中的运动污染会在重建图像中造成明显的伪影。如果在断层图像采集期间,对象在采集的一部分期间相对静止,然后显着移动,则运动后的投影数据将与相对平稳期间的投影数据不一致。扇形光束数据一致性条件(FDCC)提供了一种方法,可基于获取的所有投影数据直接估算受运动污染的投影数据。因此,FDCC可用于对抗计算机断层扫描中的多种类型的运动污染。运动伪影校正的这种方法是新颖的,因为先前的伪影校正方法均未利用运动污染数据的直接估计。另外,该方法仅取决于少量的先验信息,而不基于运动模型。该方法的另一个显着特征是它直接在投影空间中操作,并且完全独立于所使用的重建算法。使用模拟投影数据以及使用最新的64行容积CT扫描仪通过猪模型获取的投影数据,介绍了冠状动脉运动伪影减少的临床相关性示例。在模拟情况和猪模型中,都实现了与运动有关的伪影的显着减少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号